Evaluating flowability of additive manufacturing powders, using the gustavsson flow meterShow others and affiliations
2016 (English)In: World PM 2016 Congress and Exhibition, European Powder Metallurgy Association (EPMA) , 2016Conference paper, Published paper (Refereed)
Abstract [en]
The Gustavsson flow meter (including standard ISO-13517) is in this paper used to measure flow rate of fine AM powders. In the current paper, the results are compared to the Hall flow meter and a Freeman FT4 powder rheometer in terms of success of measuring these AM powders. The robustness is clearly superior to the Hall flow meter. Compared to using the rheometer, the Gustavsson flow meter is faster and simpler to use; however, other powder-aspects are evaluated since little correlation was found. All methods of characterizing the flowability could distinguish between (1) two alloys, and (2) if the alloys were new or used (in SLM), and (3) if they were dried or non-dried.
Place, publisher, year, edition, pages
European Powder Metallurgy Association (EPMA) , 2016.
Keywords [en]
3D printers, Compressive strength, Flow measurement, Flow rate, Powder metallurgy, Powders, Rheometers, Flowability, Powder rheometers, Flowmeters
National Category
Natural Sciences
Identifiers
URN: urn:nbn:se:ri:diva-42251Scopus ID: 2-s2.0-85035325109ISBN: 9781899072484 (print)OAI: oai:DiVA.org:ri-42251DiVA, id: diva2:1379552
Conference
World Powder Metallurgy 2016 Congress and Exhibition, World PM 2016, 9 October 2016 through 13 October 2016