Using deconvolution for correction of non-ideal step response of lightning impulsedigitizers and measurement systems
VTT-MIKES, Finland.
VTT-MIKES, Finland.ORCID iD: 0000-0003-1007-3089
RISE - Research Institutes of Sweden, Safety and Transport, Measurement Science and Technology.ORCID iD: 0000-0002-5121-8152
RISE - Research Institutes of Sweden, Safety and Transport, Measurement Science and Technology.
2017 (English)Conference paper, Published paper (Refereed)
Abstract [en]

Lightning impulse measurements can be highly influenced by measurement arrangement, characteristics of high voltage divider, digitizer (transient recorder) performance, and algorithms used for parameter evaluation. The main sources of measurement errors are the non-ideal step responses of digitizer and voltage divider. This paper discusses the use of deconvolution to correct for the non-ideal step response of a digitizer, and of a large mixed divider. Correcting the step response of the complete measuring system by one part at a time is desirable because it allows to evaluate the effectiveness of the correction with trustworthy methods. Step response describes the output of a system as function of time when its input changes between two levels infinitely fast. Real life impulse digitizers and impulse voltage dividers have a finite rise time, and the response does not immediately settle to final value. Slow rise time is often the cause of error for front time parameter. Creeping response is often the cause of error for time to half-value parameter. Step response of an instrument can be determined by applying a stable, known direct voltage, which is then shorted to ground by a mercury-wetted relay. The mercury-wetted relay is assumed nearly an ideal switch, which creates almost an ideal voltage step for input of the instrument. Convolving the derivative of the measured step response with an ideal input gives a measure of distortion caused by the non-perfect step response, and conversely deconvolving the measured step response with the measured signal gives the original input signal. This paper presents an FFT-based method for step response correction using deconvolution. Deconvolution is a mathematical process, which is used to reverse the non-ideal effects of measuring instrument on recorded data. Effectiveness of the method is demonstrated by two examples. In the first example, the non-ideal step responses of the different ranges of an impulse digitizer are corrected. Functionality of the step response correction is evaluated by comparing the results against a calculable impulse voltage calibrator. Results showed that the step response correction reduced errors in lightning impulse parameters. Stability of the step response correction was analysed by studying several impulse calibration results that have been performed for the instrument within a year. The second example corrects the response of a 2400 kV impulse voltage divider. The effectiveness of the correction is evaluated by comparing its results to a 400 kV reference divider.

Place, publisher, year, edition, pages
2017.
National Category
Other Natural Sciences
Identifiers
URN: urn:nbn:se:ri:diva-33481OAI: oai:DiVA.org:ri-33481DiVA, id: diva2:1188830
Conference
International Symposium on High-Voltage Engineering, 2017
Funder
European Metrology Programme for Innovation and Research (EMPIR), 14IND08
Available from: 2018-03-08 Created: 2018-03-08 Last updated: 2018-03-09Bibliographically approved

Open Access in DiVA

fulltext(619 kB)2 downloads
File information
File name FULLTEXT01.pdfFile size 619 kBChecksum SHA-512
da5c0ed5d22c924698f955dabb49e25104d920c02b4e6cbf5085efcc0e985f5129724d4dc4a10e27969825c148a75b6233c75cf00e3eebec065adf1713d92b8a
Type fulltextMimetype application/pdf

Other links

https://e-cigre.org/publication/ISH2017_381-using-deconvolution-for-correction-of-non-ideal-step-response-of-lightning-impulse-digitizers-and-measurement-systems

Search in DiVA

By author/editor
Hällström, JariBergman, Anders
By organisation
Measurement Science and Technology
Other Natural Sciences

Search outside of DiVA

GoogleGoogle Scholar
Total: 2 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 5 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
v. 2.32.0