Absolute calibration of a 100 KV DC divider
1996 (English)Conference paper, Published paper (Refereed)
Abstract [en]
An absolute determination of the ratio of a 100 kV DC divider has been made. A new Zener device that has recently become available has been used in a step-up mode to obtain the divider ratio. The uncertainty of the determination is 5.5 ppm.
Place, publisher, year, edition, pages
1996.
Keywords [en]
Zener diodes, calibration, high-voltage techniques, voltage dividers, voltage measurement, 100 kV, DC divider, Zener device, absolute calibration, divider ratio, step-up mode, uncertainty, Current measurement, Diodes, Dynamic voltage scaling, Laboratories, Low voltage, Performance evaluation, Strips, Testing
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:ri:diva-33387DOI: 10.1109/cpem.1996.547351OAI: oai:DiVA.org:ri-33387DiVA, id: diva2:1188120
Conference
Precision Electromagnetic Measurements Digest, 1996 Conference on