Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Ion beam evaluation of silicon carbide membrane structures intended for particle detectors
Lund University, Sweden.
Linköping University, Sweden; Graphensic AB, Sweden.
RISE, Swedish ICT, Acreo.
Linköping University, Sweden; Graphensic AB, Sweden.
Show others and affiliations
2016 (English)In: Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, ISSN 0168-583X, E-ISSN 1872-9584, Vol. 371, p. 132-136Article in journal (Refereed) Published
Abstract [en]

Thin ion transmission detectors can be used as a part of a telescope detector for mass and energy identification but also as a pre-cell detector in a microbeam system for studies of biological effects from single ion hits on individual living cells. We investigated a structure of graphene on silicon carbide (SiC) with the purpose to explore a thin transmission detector with a very low noise level and having mechanical strength to act as a vacuum window. In order to reach very deep cavities in the SiC wafers for the preparation of the membrane in the detector, we have studied the Inductive Coupled Plasma technique to etch deep circular cavities in 325 μm prototype samples. By a special high temperature process the outermost layers of the etched SiC wafers were converted into a highly conductive graphitic layer. The produced cavities were characterized by electron microscopy, optical microscopy and proton energy loss measurements. The average membrane thickness was found to be less than 40 μm, however, with a slightly curved profile. Small spots representing much thinner membrane were also observed and might have an origin in crystal defects or impurities. Proton energy loss measurement (also called Scanning Transmission Ion Microscopy, STIM) is a well suited technique for this thickness range. This work presents the first steps of fabricating a membrane structure of SiC and graphene which may be an attractive approach as a detector due to the combined properties of SiC and graphene in a monolithic materials structure.

Place, publisher, year, edition, pages
2016. Vol. 371, p. 132-136
Keywords [en]
Graphene, ICP, Nuclear microprobe, Transmission detector, Crystal defects, Crystal impurities, Energy dissipation, Ion beams, Ions, Membrane structures, Membranes, Silicon detectors, Silicon wafers, Biological effects, High temperature process, Inductive coupled plasma, Monolithic material, Nuclear microprobes, Scanning transmission ion microscopy, Silicon carbides (SiC), Transmission detectors, Silicon carbide
National Category
Computer and Information Sciences
Identifiers
URN: urn:nbn:se:ri:diva-32590DOI: 10.1016/j.nimb.2015.10.045Scopus ID: 2-s2.0-84960326383OAI: oai:DiVA.org:ri-32590DiVA, id: diva2:1155337
Available from: 2017-11-07 Created: 2017-11-07 Last updated: 2020-12-01Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus
By organisation
Acreo
In the same journal
Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
Computer and Information Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 23 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf