Fire safety regulations and performance of fibre-reinforced polymer composite ship structures
RISE - Research Institutes of Sweden (2017-2019), Safety and Transport, Safety. (Fire Research)ORCID iD: 0000-0001-9597-928x
RISE - Research Institutes of Sweden (2017-2019), Safety and Transport, Safety.
2017 (English)In: Journal of Engineering for the Maritime Environment (Part M), ISSN 1475-0902, E-ISSN 2041-3084, Vol. 231, no 1, p. 46-56Article in journal (Refereed) Published
Abstract [en]

This paper presents a procedure for how to relate fire performance of fibre reinforced polymer (FRP) composite structures to the fire safety regulations in SOLAS II-2. It can be used as basis when performing a fire risk assessment to demonstrate that the degree of safety is at least equivalent to that provided by prescriptive requirements. A key issue is that requirements and test methods are based on a use of steel structures, which requires seeking the safety level implied by the regulations. This was demonstrated for the regulations and introduced hazards affecting the growth stage of a fire. The safety implied by regulations was related to fire performance of FRP composite by reference to fire tests involving typical materials and some relevant safety measures. Ignition was described as uncritical whilst the fire growth on an FRP composite surface can be rapid. Flammability requirements are generally not achieved by an untreated panel but different means can be used for protection. A fire protective coating can be used to prevent ignition and sprinkler is effective both for fire prevention and extinguishment on interior and external surfaces. For interior spaces it can be relevant with a coating or thermal insulation also to hinder increased generation of smoke and toxic gases during fire evacuation. In total it is shown that fire hazards during the fire growth stage are manageable and a foundation is lain out for a well-structured fire risk assessment.

Place, publisher, year, edition, pages
2017. Vol. 231, no 1, p. 46-56
National Category
Other Natural Sciences
Identifiers
URN: urn:nbn:se:ri:diva-29410DOI: 10.1177/1475090215620449Scopus ID: 2-s2.0-85017502482OAI: oai:DiVA.org:ri-29410DiVA, id: diva2:1091860
Available from: 2017-04-28 Created: 2017-04-28 Last updated: 2023-05-16Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Evegren, Franz

Search in DiVA

By author/editor
Evegren, Franz
By organisation
Safety
In the same journal
Journal of Engineering for the Maritime Environment (Part M)
Other Natural Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 115 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf