Proficiency testing for conducted immunity with a new round robin test deviceShow others and affiliations
2016 (English)In: 2016 International Symposium on Electromagnetic Compatibility - EMC EUROPE, 2016, p. 274-279, article id 7739174Conference paper, Published paper (Refereed)
Abstract [en]
Last year, a new round robin test device was proposed for inter-laboratory comparisons in conducted immunity testing according to IEC 61000-4-6[1]. The device has recently been successfully evaluated among all EMRP Project partners. The device is able to confirm or to deny the testing capability of a laboratory by recording a full set of parameters. The device is now ready for deployment as the first commercial proficiency testing device for conducted immunity.
Place, publisher, year, edition, pages
2016. p. 274-279, article id 7739174
Keywords [en]
Auxiliary Equipment (AE), common mode, conducted immunity, Coupling-Decoupling Network (CDN), disturbance signal, Electromagnetic Compatibility (EMC), EN ISO 17025, EN ISO 17043, Equipment under Test (EUT), IEC 61000-4-6, inter-laboratory comparison, proficiency testing, round robin, test device, Auxiliary equipment, Equipment testing, Routers, Superconducting tapes, Decoupling network, Disturbance signals, Equipment under tests, Interlaboratory comparison, ISO 17025, Electromagnetic compatibility
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:ri:diva-27589DOI: 10.1109/EMCEurope.2016.7739174Scopus ID: 2-s2.0-85001129175ISBN: 978-1-5090-1416-3 (electronic)OAI: oai:DiVA.org:ri-27589DiVA, id: diva2:1057886
Conference
2016 International Symposium on Electromagnetic Compatibility (EMC EUROPE), September 5-9, 2016, Wroclaw, Poland
Note
References: Tas, E., Pythoud, F., A new conducted immunity test device for interlaboratory comparisons (2015) IEEE International Symposium on Electromagnetic Compatibility and EMC Europe; (2005) ISO/IEC 17025: General Requirements for the Competence of Testing and Calibration Laboratories, , 2nd Edition; (2010) ISO/IEC 17043: Conformity Assesment-General Requirements for Proficiency Testing, , 1st Edition; Goedbloed, J.J., Beeckman, P.A., Uncertainty of the CISPR/A radiated emission round-robin test results (2004) IEEE Transactions on Electromagnetic Compatibility, 46 (2). , May; (2013) IEC 61000-4-6 Electromagnetic Compatibility (EMC)-Part 4-6: Testing and Measurement Techniques-Immunity to Conducted Disturbances, Induced by Radio-frequency Fields, , 4th Edition, IEC
2016-12-192016-12-192020-12-01Bibliographically approved