Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Galvanic corrosion properties of steel in water saturated concrete
RISE - Research Institutes of Sweden, Material och produktion, KIMAB.ORCID-id: 0000-0001-9130-2925
RISE - Research Institutes of Sweden, Material och produktion, KIMAB.ORCID-id: 0000-0003-3930-2551
RISE - Research Institutes of Sweden, Material och produktion, KIMAB.
Lund University, Sweden.
2015 (Engelska)Ingår i: Materials and corrosion - Werkstoffe und Korrosion, ISSN 0947-5117, E-ISSN 1521-4176, Vol. 66, nr 1, s. 67-75Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Aluminum-based sacrificial anodes were installed to reinforced concrete to stop ongoing corrosion in cooling water tunnels in a Swedish nuclear power plant. The steel rebars were also unintentionally connected to stainless steel water pumps. Therefore, the consumption rate of the sacrificial anodes was higher than predicted. An experimental and a field study were performed to assess if the steel rebar suffer from galvanic corrosion and if the stainless steel pumps are responsible alone for the high consumption rate. It was found from the experimental study that there is an increased risk of galvanic corrosion for steel rebar when the corrosion potential is raised to -200mV (SCE) for samples with 1% CL- by mass of cement and -500mV (SCE) for samples with 2% Cl- by mass of cement. The experimental results were compared with the corrosion potential measured in the cooling water tunnel where sacri ficial anodes were in use and not mounted at all. The cooling water tunnel without sacrificial anodes had generally more anodic corrosion potentials compared to the tunnel with anodes. The tunnel with anodes had also more anodic potentials closer to the stainless steel pumps than further away which means that the rebar is affected by the stainless steel pumps. However, the measured corrosion potentials in the tunnels were not as anodic as the potentials needed for high galvanic current measured in the experimental study.

Ort, förlag, år, upplaga, sidor
2015. Vol. 66, nr 1, s. 67-75
Nyckelord [en]
Galvanic corrosion, Stainless steel, Steel reinforced concrete
Nationell ämneskategori
Materialteknik
Identifikatorer
URN: urn:nbn:se:ri:diva-12780DOI: 10.1002/maco.201307141Scopus ID: 2-s2.0-84920848908OAI: oai:DiVA.org:ri-12780DiVA, id: diva2:972973
Tillgänglig från: 2016-09-22 Skapad: 2016-09-22 Senast uppdaterad: 2023-05-22Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopushttp://onlinelibrary.wiley.com/doi/10.1002/maco.201307141/abstract

Person

Ahlström, JohanTidblad, Johan

Sök vidare i DiVA

Av författaren/redaktören
Ahlström, JohanTidblad, Johan
Av organisationen
KIMAB
I samma tidskrift
Materials and corrosion - Werkstoffe und Korrosion
Materialteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 245 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf