Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Designing a near zero energy supermarket - Minimising energy use and ensuring the supply of renewable energy
RISE, SP – Sveriges Tekniska Forskningsinstitut, SP Energi och Bioekonomi, Klimatisering och installationsteknik.ORCID iD: 0000-0001-8323-4459
RISE, SP – Sveriges Tekniska Forskningsinstitut, SP Energi och Bioekonomi, Klimatisering och installationsteknik.
RISE, SP – Sveriges Tekniska Forskningsinstitut, SP Energi och Bioekonomi, Klimatisering och installationsteknik.
RISE, SP – Sveriges Tekniska Forskningsinstitut, SP Energi och Bioekonomi, Klimatisering och installationsteknik.ORCID iD: 0000-0002-7949-1978
2015 (English)In: Proceedings of the 24th IIR International Congress of Refrigeration, 2015, , p. pap. n. 825p. 4008-4016Conference paper, Published paper (Refereed)
Abstract [en]

This paper describes the principles for retrofit design of Near Zero Energy supermarkets, i.e. to minimise the energy use and ensure that the remaining energy needs are met by a supply of renewable energy. Pressure for energy improvement of buildings has increased steadily over the last couple of decades. Several different aspects must be considered in the design of a supermarket - some of which are described in this paper - such as requirements, refrigerated appliances, lighting and other equipment, building technical services systems, building envelope, energy supply, energy storage, life cycle costs and consideration of the needs of those using the building. For a supermarket, special attention must be given to the food, personnel and customers, three categories with differing environmental requirements. Different designs for retrofit energy efficiency improvement installations are compared and suggested for two existing stores: one in a free-standing building, and one in a larger property.

Place, publisher, year, edition, pages
2015. , p. pap. n. 825p. 4008-4016
National Category
Natural Sciences
Identifiers
URN: urn:nbn:se:ri:diva-12597DOI: 10.18462/iir.icr.2015.0825Local ID: 29450OAI: oai:DiVA.org:ri-12597DiVA, id: diva2:970421
Conference
24th IIR International Congress of Refrigeration (ICR 2015), August 16-22, 2015, Yokohama, Japan
Available from: 2016-09-13 Created: 2016-09-13 Last updated: 2019-07-10Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full text

Authority records BETA

Lindberg, UllaRuud, Svein

Search in DiVA

By author/editor
Lindberg, UllaRuud, Svein
By organisation
Klimatisering och installationsteknik
Natural Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 31 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
v. 2.35.7