Annually, several concrete structures, such as buildings, bridges, parking garages and tunnels are exposed to fires. An assessment is then necessary to decide whether the structure can be repaired or needs to be replaced. In a recent research project, recommendations for assessments of fire exposed concrete structures have been developed. The recommendations are based on a literature survey, results from an experimental study, where ultrasonic measurements, microscopy, Digital Image Correlation (DIC) measurement on loaded core samples were used and practical experience of real post-fire structural assessments. A refined assessment of the fire damage is obtained by combining these test methods.