Capillary suction and chloride migration in fire exposed concrete with PP-fibre
RISE, SP – Sveriges Tekniska Forskningsinstitut, SP Fire Research, Brandmotstånd.
RISE, SP – Sveriges Tekniska Forskningsinstitut, SP Fire Research, Brandmotstånd.ORCID iD: 0000-0002-0380-9548
2012 (English)In: 3rd International Conference on Concrete Repair, Rehabilitation and Retrofitting III. ICCRRR 2012, 2012, , p. 128-130p. 351-357Conference paper, Published paper (Refereed)
Abstract [en]

Annually, several concrete structures, such as buildings, bridges, parking garages, tunnels, etc. are exposed to fires. Many fires are small, for example single car fires in tunnels. These fires do not affect the load carrying capability of the concrete structure and thus minor or no reparations are required. In modern concrete for civil engineer applications the use of Polypropylene fibres (PP-fibre) to reduce fire spalling is growing. Some studies have been carried out which indicate that the use of PP-fibres will not affect the durability of the concrete. But in case of a fairly moderate fire exposure, a fire exposure that does not lead to structural damage, the PP-fibres can potentially lead to reduced durability. During low intensity fires or at long distances downstream a large fire in a tunnel the PP-fibres melts and form channels in the concrete. After such degradation of the PP-fibres it is plausible that accelerated damage may occur when moisture, de-icing salts and carbon dioxide can more easily penetrate the concrete. In this experimental study the chloride migration and the capillary suction are studied in moderately heated concrete containing PP-fibres. The chloride migration tests were conducted with heated samples with and without PP-fibres. The capillary suction tests were even conducted with different fibre contents. As a reference the results are compared with results from unheated concrete. The aim of the project is to define whether or not measures have to be taken to repair concrete structures after small fires and at long distances downstream from large fires in tunnels. If the durability is affected the costs and consequences of not repairing and refurbishing after the fire can potentially be very high especially after a fires in very long tunnel.

Place, publisher, year, edition, pages
2012. , p. 128-130p. 351-357
Keywords [en]
Capillary suction, Chloride migration tests, Civil engineers, Deicing salts, Experimental studies, Fibre content, Fire exposed, Fire exposures, Load carrying capability, Low-intensity, Polypropylene fibres, Small fire, Structural damages
National Category
Natural Sciences
Identifiers
URN: urn:nbn:se:ri:diva-12192Scopus ID: 2-s2.0-84867380922Local ID: 14414OAI: oai:DiVA.org:ri-12192DiVA, id: diva2:970014
Conference
3rd International Conference on Concrete Repair, Rehabilitation and Retrofitting III. ICCRRR 2012; Cape Town; South Africa; 3-5 Sept., 2012
Available from: 2016-09-13 Created: 2016-09-13 Last updated: 2023-06-07Bibliographically approved

Open Access in DiVA

No full text in DiVA

Scopus

Authority records

Jansson, Robert

Search in DiVA

By author/editor
Jansson, Robert
By organisation
Brandmotstånd
Natural Sciences

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 113 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf