Optimisation of Pulsed Ultrasonic Velocimetry system and transducer technology for industrial applications
RISE., SP – Sveriges Tekniska Forskningsinstitut, SP Sveriges tekniska forskningsinstitut, SIK – Institutet för livsmedel och bioteknik.ORCID-id: 0000-0002-7856-2324
2013 (engelsk)Inngår i: Ultrasonics, ISSN 0041-624X, E-ISSN 1874-9968, Vol. 53, nr 2, s. 459-469Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Pulsed Ultrasonic Velocimetry, commonly referred to as Ultrasonic Velocity Profiling (UVP) in research and engineering applications, is both a method and a device to measure an instantaneous one-dimensional velocity profile in opaque fluids along a measurement axis by using Doppler echography. Studies have suggested that the accuracy of the measured velocity gradient close to wall interfaces need to be improved. The reason for this is due to distortion caused by cavities situated in front of ultrasonic transducers, measurement volumes overlapping wall interfaces, refraction of the ultrasonic wave as well as sound velocity variations (Doppler angle changes). In order to increase the accuracy of velocity data close to wall interfaces and solve previous problems a specially designed delay line transducer was acoustically characterised and evaluated. Velocity profiles measured using the delay line transducer, were initially distorted due to the effect of finite sample volume characteristics and propagation through the delay line material boundary layers. These negative effects were overcome by measuring physical properties of the ultrasonic beam and implementing a newly developed deconvolution procedure. Furthermore, custom velocity estimation algorithms were developed, which improved the time resolution and penetration depth of the UVP system. The optimised UVP system was evaluated and compared to standard transducers in three different straight pipes (inner diameters of 16, 22.5 and 52.8 mm). Velocity data obtained using the optimised UVP system showed significant improvement close to wall interfaces where the velocity gradients are high. The new transducer technology and signal processing techniques reduced previously mentioned problems and are now more suitable for industrial process monitoring and control. © 2012 Elsevier B.V. All rights reserved.

sted, utgiver, år, opplag, sider
2013. Vol. 53, nr 2, s. 459-469
Emneord [en]
Food Engineering
Emneord [sv]
Livsmedelsteknik
HSV kategori
Identifikatorer
URN: urn:nbn:se:ri:diva-9427DOI: 10.1016/j.ultras.2012.08.014OAI: oai:DiVA.org:ri-9427DiVA, id: diva2:967302
Tilgjengelig fra: 2016-09-08 Laget: 2016-09-08 Sist oppdatert: 2018-07-20bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fullteksthttp://www.scopus.com/inward/record.url?eid=2-s2.0-84870247075&partnerID=40&md5=2bf1d995f6385f3812f7ea8f301e4760

Personposter BETA

Wiklund, Johan

Søk i DiVA

Av forfatter/redaktør
Wiklund, Johan
Av organisasjonen
I samme tidsskrift
Ultrasonics

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 11 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
v. 2.35.8