Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Effect of cross section and ventilation on heat release rates in tunnel fires
Hefei University of Technology, China.
RISE., SP – Sveriges Tekniska Forskningsinstitut, SP Sveriges tekniska forskningsinstitut, SP – Sveriges Tekniska Forskningsinstitut / Brandteknik, skydd (BRs ).ORCID-id: 0000-0002-9340-6768
RISE., SP – Sveriges Tekniska Forskningsinstitut, SP Sveriges tekniska forskningsinstitut, SP – Sveriges Tekniska Forskningsinstitut / Brandteknik, skydd (BRs ).ORCID-id: 0000-0001-6758-6067
Vise andre og tillknytning
2016 (engelsk)Inngår i: Tunnelling and Underground Space Technology, ISSN 0886-7798, E-ISSN 1878-4364, Vol. 51, s. 414-423Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Model scale fire tests were performed in tunnels with varying tunnel widths and heights in order to study the effect of tunnel cross-section and ventilation velocity on the heat release rate (HRR) for both liquid pool fires and solid fuel fires. The results showed that for well ventilated heptane pool fires, the tunnel width nearly has no influence on the HRR whilst a lower tunnel height clearly increases the HRR. For well ventilated solid fuel fires, the HRR increases by approximately 25% relative to a free burn test but the HRR is not sensitive to either tunnel width, tunnel height or ventilation velocity. For solid fuel fires that were not well ventilated, the HRRs could be less than those in free burn laboratory tests. In the case of ventilation controlled fires the HRRs approximately lie at the same level as for cases with natural ventilation.

sted, utgiver, år, opplag, sider
2016. Vol. 51, s. 414-423
Emneord [en]
Cross section, Heat release rate, Tunnel fire, Ventilation
HSV kategori
Identifikatorer
URN: urn:nbn:se:ri:diva-6928DOI: 10.1016/j.tust.2015.09.007Scopus ID: 2-s2.0-84948843862Lokal ID: 30761OAI: oai:DiVA.org:ri-6928DiVA, id: diva2:964770
Tilgjengelig fra: 2016-09-08 Laget: 2016-09-08 Sist oppdatert: 2023-06-08bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Li, Ying ZhenIngason, HaukurLönnermark, Anders

Søk i DiVA

Av forfatter/redaktør
Li, Ying ZhenIngason, HaukurLönnermark, Anders
Av organisasjonen
I samme tidsskrift
Tunnelling and Underground Space Technology

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 86 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
v. 2.43.0