Comparison of Co–C Eutectic-Point Cells for Thermocouple Calibration Between SP and NMIJ
National Metrology Institute of Japan, Japan.
RISE., SP – Sveriges Tekniska Forskningsinstitut.
RISE., SP – Sveriges Tekniska Forskningsinstitut, SP Mätteknik, Volym, flöde, temperatur o densitet.
2014 (engelsk)Inngår i: International journal of thermophysics, ISSN 0195-928X, E-ISSN 1572-9567, Vol. 36, nr 2-3, s. 399-412Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

As recently reported, the metal–carbon eutectic points seem to be useful as practical reference points for calibrating thermocouples. The melting temperature of the cobalt–carbon eutectic point (Co–C, 1324◦C) is an ideal solution for a reference point being at approximately the middle between the freezing point of copper (1084.62◦C) and the melting point of palladium (1554.8◦C). In this study, a comparison of reference Co–C cells used for thermocouple calibration service was performed between the Technical Institute of Sweden (SP) and the National Metrology Institute of Japan (NMIJ) by means of two circulating Pt/Pd thermocouples and one circulating Co–C cell in order to investigate the reliability of thermocouple calibration at the Co–C eutectic point. The reference Co–C cell at SP was designed and constructed in the National Physical Laboratory (NPL), and provided to SP, while the reference Co–C cell at NMIJ as well as the circulating cell was designed and constructed at NMIJ. The melting temperature of the reference Co–C cells at SP and NMIJ were evaluated by using the calibrated radiation thermometers at NPL and NMIJ, respectively, prior to the circulation of the thermocouples and the cell between SP and NMIJ. The temperature difference between the reference cells of SP and NMIJ, as measured by means of the circulating thermocouples, was found to be within 0.33◦C, while that measured by means of the circulating cell was found to be within 0.22◦C. The temperature of reference cells at SP and NMIJ was found to agree within an expanded uncertainty (k=2) in spite of different temperature traceability chains. This means that the calibration of thermocouples at the Co–C eutectic point was sufficiently reliable.

sted, utgiver, år, opplag, sider
2014. Vol. 36, nr 2-3, s. 399-412
HSV kategori
Identifikatorer
URN: urn:nbn:se:ri:diva-6701DOI: 10.1007/s10765-014-1750-xScopus ID: 2-s2.0-84925515532Lokal ID: 23696OAI: oai:DiVA.org:ri-6701DiVA, id: diva2:964541
Tilgjengelig fra: 2016-09-08 Laget: 2016-09-08 Sist oppdatert: 2020-12-01bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus
Av organisasjonen
I samme tidsskrift
International journal of thermophysics

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 29 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
v. 2.43.0