Intercomparison of lateral scales of scanning electron microscopes and atomic force microscopes in research institutes in Northern Europe
MIKES Centre for Metrology and Accreditation, Finland.
MIKES Centre for Metrology and Accreditation, Finland.
RISE., SP – Sveriges Tekniska Forskningsinstitut, SP Mätteknik, Massa, kraft, längd och tryck.ORCID-id: 0000-0001-5203-5465
Justervesenet, Norway.
Vise andre og tillknytning
2014 (engelsk)Inngår i: Measurement science and technology, ISSN 0957-0233, E-ISSN 1361-6501, Vol. 25, nr 4, artikkel-id 44013Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

An intercomparison of lateral scales of scanning electron microscopes (SEM) and atomic force microscopes (AFM) in various research laboratories in Northern Europe was organized by the local national metrology institutes. In this paper are presented the results of the comparison, with also an example uncertainty budget for AFM grating pitch measurement. Grating samples (1D) were circulated among the participating laboratories. The participating laboratories were also asked about the calibration of their instruments. The accuracy of the uncertainty estimates seemed to vary largely between the laboratories, and for some laboratories the appropriateness of the calibration procedures could be considered. Several institutes (60% of all results in terms of En value) also had good comprehension of their measurement capability. The average difference from reference value was 6.7 and 10.0 nm for calibrated instruments and 20.6 and 39.9 nm for uncalibrated instruments for 300 nm and 700 nm gratings, respectively. The correlation of the results for both nominally 300 and 700 nm gratings shows that a simple scale factor calibration would have corrected a large part of the deviations from the reference values.

sted, utgiver, år, opplag, sider
2014. Vol. 25, nr 4, artikkel-id 44013
HSV kategori
Identifikatorer
URN: urn:nbn:se:ri:diva-6685DOI: 10.1088/0957-0233/25/4/044013Scopus ID: 2-s2.0-84896778155Lokal ID: 23674OAI: oai:DiVA.org:ri-6685DiVA, id: diva2:964525
Tilgjengelig fra: 2016-09-08 Laget: 2016-09-08 Sist oppdatert: 2023-06-08bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Bergstrand, Sten

Søk i DiVA

Av forfatter/redaktør
Bergstrand, Sten
Av organisasjonen
I samme tidsskrift
Measurement science and technology

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 45 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
v. 2.43.0