Intercomparison of lateral scales of scanning electron microscopes and atomic force microscopes in research institutes in Northern Europe
MIKES Centre for Metrology and Accreditation, Finland.
MIKES Centre for Metrology and Accreditation, Finland.
RISE., SP – Sveriges Tekniska Forskningsinstitut, SP Mätteknik, Massa, kraft, längd och tryck.ORCID-id: 0000-0001-5203-5465
Justervesenet, Norway.
Visa övriga samt affilieringar
2014 (Engelska)Ingår i: Measurement science and technology, ISSN 0957-0233, E-ISSN 1361-6501, Vol. 25, nr 4, artikel-id 44013Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

An intercomparison of lateral scales of scanning electron microscopes (SEM) and atomic force microscopes (AFM) in various research laboratories in Northern Europe was organized by the local national metrology institutes. In this paper are presented the results of the comparison, with also an example uncertainty budget for AFM grating pitch measurement. Grating samples (1D) were circulated among the participating laboratories. The participating laboratories were also asked about the calibration of their instruments. The accuracy of the uncertainty estimates seemed to vary largely between the laboratories, and for some laboratories the appropriateness of the calibration procedures could be considered. Several institutes (60% of all results in terms of En value) also had good comprehension of their measurement capability. The average difference from reference value was 6.7 and 10.0 nm for calibrated instruments and 20.6 and 39.9 nm for uncalibrated instruments for 300 nm and 700 nm gratings, respectively. The correlation of the results for both nominally 300 and 700 nm gratings shows that a simple scale factor calibration would have corrected a large part of the deviations from the reference values.

Ort, förlag, år, upplaga, sidor
2014. Vol. 25, nr 4, artikel-id 44013
Nationell ämneskategori
Naturvetenskap
Identifikatorer
URN: urn:nbn:se:ri:diva-6685DOI: 10.1088/0957-0233/25/4/044013Scopus ID: 2-s2.0-84896778155Lokalt ID: 23674OAI: oai:DiVA.org:ri-6685DiVA, id: diva2:964525
Tillgänglig från: 2016-09-08 Skapad: 2016-09-08 Senast uppdaterad: 2023-06-08Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Bergstrand, Sten

Sök vidare i DiVA

Av författaren/redaktören
Bergstrand, Sten
Av organisationen
Massa, kraft, längd och tryck
I samma tidskrift
Measurement science and technology
Naturvetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 45 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf