Investigation of a ten-path ultrasonic flow meter for accurate feedwater measurements
PTB Physikalisch-Technische Bundesanstalt, Germany.
RISE., SP – Sveriges Tekniska Forskningsinstitut, SP Mätteknik, Volym, flöde, temperatur o densitet.ORCID-id: 0000-0001-5118-0150
KROHNE Altometer, The Netherlands.
PTB Physikalisch-Technische Bundesanstalt, Germany.
2014 (engelsk)Inngår i: Measurement science and technology, ISSN 0957-0233, E-ISSN 1361-6501, Vol. 25, nr 7, s. 75304-Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The flow instruments used in thermal power plants cannot be calibrated directly for the actual process conditions, since no traceable calibration facility with known uncertainty is available. Asystematic investigation of the relevant influence parameters is therefore needed. It was found in earlier investigations that the dominant influences on the measurement uncertainty are the flowvelocity profile and the temperature. In the present work, we report on our experimental study of the temperature and Reynolds number dependence of a new ten-path ultrasonic flow meterprototype. An improved measuring program is developed that allows for a systematic characterization. Special emphasis was placed on producing and validating well defined velocity profiles on aprecision calibration flow rig. It was also for the first time intended and validated to generate fully developed Reynolds-similar velocity profiles for different temperatures so that the two main influence parameters, namely temperature and Reynolds number, can be clearly characterized separately. Since such ideal measurement conditions are not found in practical applications, the approach is also tested for a disturbed flow condition. A well defined disturbance is generated with a new flow disturber.

sted, utgiver, år, opplag, sider
2014. Vol. 25, nr 7, s. 75304-
HSV kategori
Identifikatorer
URN: urn:nbn:se:ri:diva-6674DOI: 10.1088/0957-0233/25/7/075304Scopus ID: 2-s2.0-84902438521Lokal ID: 23653OAI: oai:DiVA.org:ri-6674DiVA, id: diva2:964514
Tilgjengelig fra: 2016-09-08 Laget: 2016-09-08 Sist oppdatert: 2020-12-01bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Büker, Oliver

Søk i DiVA

Av forfatter/redaktør
Büker, Oliver
Av organisasjonen
I samme tidsskrift
Measurement science and technology

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 47 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
v. 2.43.0