Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Application of ultrasound Doppler technique for in-line rheological characterization and flow visualization of concentrated suspensions
Cape Peninsula University of Technology, South Africa.
RISE., SP – Sveriges Tekniska Forskningsinstitut.ORCID-id: 0000-0002-7856-2324
Cape Peninsula University of Technology, South Africa.
2016 (engelsk)Inngår i: Canadian Journal of Chemical Engineering, ISSN 0008-4034, E-ISSN 1939-019X, Vol. 94, nr 6, s. 1066-1075Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Ultrasonic velocity profiling (UVP) is a technique that can measure an instantaneous one-dimensional velocity profile in a fluid containing particles across the ultrasonic beam axis or measurement line. A method for in-line rheometry combining the UVP technique with pressure difference (PD) measurements (UVP+PD), was developed and improved at SP - Technical Research Institute of Sweden and the Cape Peninsula University of Technology, South Africa. The UVP+PD methodology allows measurements that are not possible with common rheometers such as radial velocity profiles and yield stress directly in-line and under true dynamic process conditions. Furthermore, it has advantages over commercially available process rheometers and offline instruments in being non-invasive, applicable to opaque and concentrated suspensions, and having small sensor dimensions. It has been evaluated for several potential industrial applications including paper pulp, foods, transient flows, and model mineral suspensions. Similarly, the UVP technique can be applied to an open-channel flow by combining flow depth measurements to obtain rheological properties in-line. Industrial fluids, such as thickened pastes, commonly found in tailings transportation exhibit wide particle size distributions, large particle sizes, and very high viscosities. These industrial fluids cause strong attenuation of the ultrasound energy, which can significantly distort velocity profiles measured with the UVP technique or even make it impossible to conduct flow measurements. Initial results obtained in concentrated cement pastes and grouts (bentonite and kaolin clay) showed that UVP is a feasible and promising technique for flow characterization in viscous fluids.

sted, utgiver, år, opplag, sider
Wiley-Liss Inc. , 2016. Vol. 94, nr 6, s. 1066-1075
Emneord [en]
Non-Newtonian, Open channel, Rheology, Ultrasonic velocity profiling, UVP+PD methodology
HSV kategori
Identifikatorer
URN: urn:nbn:se:ri:diva-406DOI: 10.1002/cjce.22486OAI: oai:DiVA.org:ri-406DiVA, id: diva2:941623
Tilgjengelig fra: 2016-06-22 Laget: 2016-06-22 Sist oppdatert: 2019-06-11bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Personposter BETA

Wiklund, Johan

Søk i DiVA

Av forfatter/redaktør
Wiklund, Johan
Av organisasjonen
I samme tidsskrift
Canadian Journal of Chemical Engineering

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 13 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
v. 2.35.8