Calibration of insulin pumps based on discrete doses at given cycle times
METAS Federal Institute of Metrology, Switzerland.
RISE Research Institutes of Sweden, Säkerhet och transport, Mätteknik.ORCID-id: 0000-0001-5118-0150
RISE Research Institutes of Sweden, Säkerhet och transport, Mätteknik.ORCID-id: 0000-0003-2334-065X
IPQ Metrology Department, Portugal.
Visa övriga samt affilieringar
2023 (Engelska)Ingår i: Biomedizinische Technik (Berlin. Zeitschrift), ISSN 1862-278X, E-ISSN 0013-5585, Vol. 68, nr 1, s. 67-77Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

One application in the medical treatment at very small flow rates is the usage of an Insulin pump that delivers doses of insulin at constant cycle times for a specific basal rate as quasi-continuous insulin delivery, which is an important cornerstone in diabetes management. The calibration of these basal rates are performed by either gravimetric or optical methods, which have been developed within the European Metrology Program for Innovation and Research (EMPIR) Joint Research Project (JRP) 18HLT08 Metrology for drug delivery II (MeDDII). These measurement techniques are described in this paper, and an improved approach of the analytical procedure given in the standard IEC 60601-2-24:2012 for determining the discrete doses and the corresponding basal rates is discussed in detail. These improvements allow detailed follow up of dose cycle time and delivered doses as a function of time to identify some artefacts of the measurement method or malfunctioning of the insulin pump. Moreover, the calibration results of different basal rates and bolus deliveries for the gravimetric and the optical methods are also presented. Some analysis issues that should be addressed to prevent misinterpreting of the calibration results are discussed. One of the main issues is the average over a period of time which is an integer multiple of the cycle time to determine the basal rate with the analytical methods described in this paper. 

Ort, förlag, år, upplaga, sidor
De Gruyter Open Ltd , 2023. Vol. 68, nr 1, s. 67-77
Nyckelord [en]
calibration, dose accuracy, insulin pump, traceability, Controlled drug delivery, Insulin, Pumps, Targeted drug delivery, Cycle time, Diabetes management, Insulin delivery, Insulin pumps, Medical treatment, Optical methods, Pump-based, Small flow-rate
Nationell ämneskategori
Klinisk medicin
Identifikatorer
URN: urn:nbn:se:ri:diva-61247DOI: 10.1515/bmt-2022-0040Scopus ID: 2-s2.0-85139486442OAI: oai:DiVA.org:ri-61247DiVA, id: diva2:1714861
Anmärkning

Funding details: Horizon 2020 Framework Programme, H2020; Funding details: European Metrology Programme for Innovation and Research, EMPIR; Funding text 1: Research funding: This project 18HLT08 MEDDII has received funding from the EMPIR programme co-financed by the Participating States and from the European Union’s Horizon 2020 research and innovation programme.

Tillgänglig från: 2022-11-30 Skapad: 2022-11-30 Senast uppdaterad: 2024-04-17Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Büker, OliverStolt, Krister

Sök vidare i DiVA

Av författaren/redaktören
Büker, OliverStolt, Krister
Av organisationen
Mätteknik
I samma tidskrift
Biomedizinische Technik (Berlin. Zeitschrift)
Klinisk medicin

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 45 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf