Calibration of insulin pumps based on discrete doses at given cycle times
METAS Federal Institute of Metrology, Switzerland.
RISE Research Institutes of Sweden, Säkerhet och transport, Mätteknik.ORCID-id: 0000-0001-5118-0150
RISE Research Institutes of Sweden, Säkerhet och transport, Mätteknik.ORCID-id: 0000-0003-2334-065X
IPQ Metrology Department, Portugal.
Vise andre og tillknytning
2023 (engelsk)Inngår i: Biomedizinische Technik (Berlin. Zeitschrift), ISSN 1862-278X, E-ISSN 0013-5585, Vol. 68, nr 1, s. 67-77Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

One application in the medical treatment at very small flow rates is the usage of an Insulin pump that delivers doses of insulin at constant cycle times for a specific basal rate as quasi-continuous insulin delivery, which is an important cornerstone in diabetes management. The calibration of these basal rates are performed by either gravimetric or optical methods, which have been developed within the European Metrology Program for Innovation and Research (EMPIR) Joint Research Project (JRP) 18HLT08 Metrology for drug delivery II (MeDDII). These measurement techniques are described in this paper, and an improved approach of the analytical procedure given in the standard IEC 60601-2-24:2012 for determining the discrete doses and the corresponding basal rates is discussed in detail. These improvements allow detailed follow up of dose cycle time and delivered doses as a function of time to identify some artefacts of the measurement method or malfunctioning of the insulin pump. Moreover, the calibration results of different basal rates and bolus deliveries for the gravimetric and the optical methods are also presented. Some analysis issues that should be addressed to prevent misinterpreting of the calibration results are discussed. One of the main issues is the average over a period of time which is an integer multiple of the cycle time to determine the basal rate with the analytical methods described in this paper. 

sted, utgiver, år, opplag, sider
De Gruyter Open Ltd , 2023. Vol. 68, nr 1, s. 67-77
Emneord [en]
calibration, dose accuracy, insulin pump, traceability, Controlled drug delivery, Insulin, Pumps, Targeted drug delivery, Cycle time, Diabetes management, Insulin delivery, Insulin pumps, Medical treatment, Optical methods, Pump-based, Small flow-rate
HSV kategori
Identifikatorer
URN: urn:nbn:se:ri:diva-61247DOI: 10.1515/bmt-2022-0040Scopus ID: 2-s2.0-85139486442OAI: oai:DiVA.org:ri-61247DiVA, id: diva2:1714861
Merknad

Funding details: Horizon 2020 Framework Programme, H2020; Funding details: European Metrology Programme for Innovation and Research, EMPIR; Funding text 1: Research funding: This project 18HLT08 MEDDII has received funding from the EMPIR programme co-financed by the Participating States and from the European Union’s Horizon 2020 research and innovation programme.

Tilgjengelig fra: 2022-11-30 Laget: 2022-11-30 Sist oppdatert: 2024-04-17bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Büker, OliverStolt, Krister

Søk i DiVA

Av forfatter/redaktør
Büker, OliverStolt, Krister
Av organisasjonen
I samme tidsskrift
Biomedizinische Technik (Berlin. Zeitschrift)

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 45 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
v. 2.43.0