Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Funktionsprovning av tätskiktsystem för våtutrymmen 2022
RISE Research Institutes of Sweden, Built Environment, Building and Real Estate.ORCID iD: 0000-0002-8705-2828
RISE Research Institutes of Sweden, Built Environment, Infrastructure and concrete technology.
RISE Research Institutes of Sweden, Built Environment, Infrastructure and concrete technology.
RISE Research Institutes of Sweden, Materials and Production, Polymeric Materials and Composites.
Show others and affiliations
2022 (Swedish)Report (Other academic)
Abstract [en]

Functional testing of waterproofing systems for use behind ceramic tiling based on flexible sheets 2022 This research project is a repetition of previously completed projects. These projects span a long period of time, 12 years. The projects were completed during the period 2010 to 2022. Functional testing The result is better than before. 2022 2019 (1) 2016 (2) 2014 (3) 2010 (4) Result Result Result Result Result Result No leakage 9 (47 %) 6 (32 %) 8 (40 %) 3 (15 %) 0 (0 %) Leakage 10 (53 %) 13 (68 %) 12 (60 %) 17 (85 %) 5 (100 %) In this investigation, most of the leaks are located to penetrations of large and small sewer pipes. In this investigation, we have on several occasions seen that the pipe sleeves have had substandard quality. This has manifested itself in the fact that the polymeric material which is to seal around the pipe during the test has lost its sealing ability. It is probable that the material has developed a residual deformation (settling) which means that the material has lost its ability to seal around the pipe. We have also noticed that pipe cuffs have delaminated, the layers in the cuff during the test have been divided into their components. Leakage has also occurred at inner corners, outer corners and at chafing. Only a few, two, leaks at connections to floor drains have been noted. Better yet, none of the examined waterproofing systems showed leaks that were so extensive that one can speak of a total damage. Water vapour resistance and mass per unit area The vast majority of investigated waterproofing foils have a water vapour resistance of between 2.5 and 4.5 million s m, which is a high or very high value. Results for five waterproofing foils fall below 2.5 million s / m. Based on the determinations of water vapor resistance and basis weight, it can be concluded that probably six of the waterproofing suppliers have developed new or changed foils since the last survey. The trend of wanting to make thinner foils seems to have been broken. Most of the waterproofing foils have a higher vapor passage resistance now than in the previous survey. It is also noteworthy that the PVC sealing layer has a low water vapor passage resistance. The waterproofing foil has basically the same basis weight now compared to the previous survey. Indication of long-term properties To obtain an indication of the amount of added antioxidants that improve the long-term properties of the materials, DSC analyses of the waterproofing foils have been performed. Compared with the previous study, the induction temperatures are at about the same level as before, only small differences occur. The average induction temperature for all polyethylene films is 216 ° C and, in summary, the materials appear to be stabilized at the same level as the previous study. In the same way as in the survey, 2016, most materials seem to be more stabilized for long-term use compared with the previous study, 2014. However, for all analysed materials, to make a reliable service life prediction of the material, a more comprehensive aging study is recommended

Place, publisher, year, edition, pages
2022. , p. 89
Series
RISE Rapport ; 2022:15
Keywords [en]
Functional test, waterproofing system, wet room
National Category
Building Technologies
Identifiers
URN: urn:nbn:se:ri:diva-58978ISBN: 978-91-89561-30-4 (electronic)OAI: oai:DiVA.org:ri-58978DiVA, id: diva2:1651280
Available from: 2022-04-11 Created: 2022-04-11 Last updated: 2023-06-08Bibliographically approved

Open Access in DiVA

fulltext(6377 kB)233 downloads
File information
File name FULLTEXT01.pdfFile size 6377 kBChecksum SHA-512
612e6c8c6a6baed39a4b291253299362a28b01c7a9063b3622ec42b9be6b7470f996270a727b678cdc76f8344793df66dcfbeb8315821e9aad84ff881d26dfd7
Type fulltextMimetype application/pdf

Authority records

Antonsson, Ulf

Search in DiVA

By author/editor
Antonsson, Ulf
By organisation
Building and Real EstateInfrastructure and concrete technologyPolymeric Materials and Composites
Building Technologies

Search outside of DiVA

GoogleGoogle Scholar
Total: 233 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

isbn
urn-nbn

Altmetric score

isbn
urn-nbn
Total: 558 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf