Determining the Impact of High Residential Density on Indoor Environment, Energy Use, and Moisture Loads in Swedish Apartments-and Measures for Mitigation
Lund University, Sweden.
RISE Research Institutes of Sweden, Samhällsbyggnad, Systemomställning och tjänsteinnovation. Lund University, Sweden.ORCID-id: 0000-0001-7568-3334
RISE Research Institutes of Sweden. Lund University, Sweden.ORCID-id: 0000-0002-3863-0740
Lund University, Sweden.
Vise andre og tillknytning
2021 (engelsk)Inngår i: Sustainability, E-ISSN 2071-1050, Vol. 13, nr 10, artikkel-id 5446Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Recently, there has been an increase in apartments with a large number of inhabitants, i.e., high residential density. This is partly due to a housing shortage in general but also increased migration, particularly in suburbs of major cities. This paper specifies issues that might be caused by high residential density by investigating the technical parameters influenced in Swedish apartments that are likely to have high residential density. Interviews with 11 employees at housing companies were conducted to identify issues that might be caused by high residential density. Furthermore, simulations were conducted based on extreme conditions described in the interviews to determine the impact on the energy use, indoor environmental quality, and moisture loads. In addition, the impact of measures to mitigate the identified issues was determined. Measures such as demand-controlled ventilation, increase of a constant ventilation rate, and moisture buffering are shown to reduce the risk for thermal discomfort, mold growth, and diminished indoor air quality; while still achieving a lower energy use than in a normally occupied apartment. The results of this study can be used by authorities to formulate incentives and/or recommendations for housing owners to implement measures to ensure good indoor environmental quality for all, irrespective of residential density conditions.

sted, utgiver, år, opplag, sider
2021. Vol. 13, nr 10, artikkel-id 5446
Emneord [en]
family size, residential density, energy use, moisture loads, indoor environmental quality, mitigating measures
HSV kategori
Identifikatorer
URN: urn:nbn:se:ri:diva-53117DOI: 10.3390/su13105446OAI: oai:DiVA.org:ri-53117DiVA, id: diva2:1555649
Tilgjengelig fra: 2021-05-19 Laget: 2021-05-19 Sist oppdatert: 2023-05-25bibliografisk kontrollert

Open Access i DiVA

fulltext(2703 kB)302 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 2703 kBChecksum SHA-512
edcf116f443b9fab6d00430b99b948e8a3d191c3f33254fbf7e3f0a78189e044d1c9e056c5a86c1d2452905ca42d8fc8c8f4683a010706365fae8566b124733b
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekst

Person

von Platten, JennyMjörnell, Kristina

Søk i DiVA

Av forfatter/redaktør
von Platten, JennyMjörnell, Kristina
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 305 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 240 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
v. 2.43.0