Planning and operation of an integrated energy system in a Swedish building
KTH Royal Institute of Technology, Sweden.
KTH Royal Institute of Technology, Sweden; Mälardalen University, Sweden.
RISE - Research Institutes of Sweden, Säkerhet och transport, Elektronik.ORCID-id: 0000-0002-1226-0788
Tianjin University, China.
Visa övriga samt affilieringar
2019 (Engelska)Ingår i: Energy Conversion and Management, ISSN 0196-8904, E-ISSN 1879-2227, Vol. 199, artikel-id 111920Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

More flexibility measures are required due to the increasing capacities of variable renewable energies (VRE). In buildings, the integration of energy supplies forms integrated energy systems (IES). IESs can provide flexibility and increase the VRE penetration level. To upgrade a current building energy system into an IES, several energy conversion and storage components are needed. How to decide the component capacities and operate the IES were investigated separately in studies on system planning and system operation. However, a research gap exists that the system configuration from system planning is not validated by actual operation conditions in system operation. Meanwhile, studies on system operation assume that IES configurations are predetermined. This work combines system planning and system operation. The IES configuration is determined by mixed integer linear programming in system planning. Actual operation conditions and forecast errors are considered in system operation. The actual operation profiles are obtained through year-round simulations of different energy management systems. The results indicate that the system configuration from system planning can meet energy demands in system operation. Among different energy management systems, the combination of robust optimization and receding horizon optimization achieves the lowest yearly operation cost. Meanwhile, two scenarios that represent high and low forecast accuracies are studied. Under the high and low forecast accuracy scenarios, the yearly operation costs are about 4% and 6% higher than that obtained from system planning.

Ort, förlag, år, upplaga, sidor
Elsevier Ltd , 2019. Vol. 199, artikel-id 111920
Nyckelord [en]
Building, Integrated energy system, MILP, Planning and operation, Robust optimization
Nationell ämneskategori
Naturvetenskap
Identifikatorer
URN: urn:nbn:se:ri:diva-39915DOI: 10.1016/j.enconman.2019.111920Scopus ID: 2-s2.0-85071397120OAI: oai:DiVA.org:ri-39915DiVA, id: diva2:1356523
Anmärkning

 Funding details: China Scholarship Council, CSC; Funding text 1: This work has received funding from KKS Future Energy Profile through the project iREST and FREE. Yang Zhang acknowledges the financial support from China Scholarship Council (CSC).

Tillgänglig från: 2019-10-01 Skapad: 2019-10-01 Senast uppdaterad: 2019-10-01Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Lundblad, Anders Olof

Sök vidare i DiVA

Av författaren/redaktören
Lundblad, Anders Olof
Av organisationen
Elektronik
I samma tidskrift
Energy Conversion and Management
Naturvetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 67 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf