Overcurrent Abuse of Primary Prismatic Zinc–Air Battery Cells Studying Air Supply Effects on Performance and Safety Shut-Down
RISE - Research Institutes of Sweden, Säkerhet och transport, Elektronik. Chalmers University of Technology, Sweden.ORCID-id: 0000-0001-5364-449x
Chalmers University of Technology, Sweden.
Volvo Group Trucks Technology, Sweden.
University of Gothenburg, Sweden.
Vise andre og tillknytning
2017 (engelsk)Inngår i: Batteries, ISSN 2313-0105, Vol. 3, nr 1, s. 1-10Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Overcurrent abuse has been performed on commercial 48 Ah primary prismatic zinc (Zn)–Air battery cells with full air supply as well as with shut-off air supply. Compared to other battery technologies, e.g., lithium-ion batteries, metal–air batteries offer the possibility to physically stop the battery operation by stopping its air supply, thus offering an additional protection against severe battery damage in the case of, e.g., an accidental short circuit. This method may also reduce the electrical hazard in a larger battery system since, by stopping the air supply, the voltage can be brought to zero while maintaining the energy capacity of the battery. Measurements of Overdischarge currents and current cut-off by suffocation have been performed to assess the safety of this type of Zn–air battery. The time to get to zero battery voltage is shown to mainly be determined by the volume of air trapped in the cell.

sted, utgiver, år, opplag, sider
2017. Vol. 3, nr 1, s. 1-10
Emneord [en]
abuse, air supply, metal–air, overcurrent, overdischarge, primary battery, safety, suffocation, zinc (Zn)–air
HSV kategori
Identifikatorer
URN: urn:nbn:se:ri:diva-32899DOI: 10.3390/batteries3010001OAI: oai:DiVA.org:ri-32899DiVA, id: diva2:1168449
Forskningsfinansiär
Swedish Energy Agency, 35755-1Tilgjengelig fra: 2017-12-20 Laget: 2017-12-20 Sist oppdatert: 2018-08-23bibliografisk kontrollert

Open Access i DiVA

fulltext(4589 kB)38 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 4589 kBChecksum SHA-512
98f9479d3391f16a281e98c378a641b223c1e51a3edac72fbfc5a903af0eae6eaf47c27a547932c29d138a4ef536c82eb7559ee95be69cd734b9ff85e6335d59
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fullteksthttp://www.mdpi.com/2313-0105/3/1/1

Personposter BETA

Larsson, Fredrik

Søk i DiVA

Av forfatter/redaktør
Larsson, Fredrik
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 38 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 76 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
v. 2.35.8