Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
A new flow-through bioassay for testing low-emission antifouling coatings
GEOMAR Helmholtz Centre for Ocean Research Kiel, Germany; University of Gothenburg, Sweden.
University of Gothenburg, Sweden.
RISE - Research Institutes of Sweden, Biovetenskap och material, Kemi och material.ORCID-id: 0000-0002-9377-8924
RISE - Research Institutes of Sweden, Biovetenskap och material, Kemi och material.ORCID-id: 0000-0002-8945-9904
Visa övriga samt affilieringar
2017 (Engelska)Ingår i: Biofouling (Print), ISSN 0892-7014, E-ISSN 1029-2454, Vol. 33, nr 8, s. 613-623Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Current antifouling (AF) technologies are based on the continuous release of biocides into the water, and consequently discharge into the environment. Major efforts to develop more environmentally friendly coatings require efficient testing in laboratory assays, followed by field studies. Barnacles are important fouling organisms worldwide, increasing hydrodynamic drag on ships and damaging coatings on underwater surfaces, and thus are extensively used as models in AF research, mostly in static, laboratory-based systems. Reliable flow-through test assays for the screening of biocide-containing AF paints, however, are rare. Herein, a flow-through bioassay was developed to screen for diverse low-release biocide paints, and to evaluate their effects on pre- and post-settlement traits in barnacles. The assay distinguishes between the effects from direct surface contact and bulk-water effects, which are crucial when developing low-emission AF coatings. This flow-through bioassay adds a new tool for rapid laboratory-based first-stage screening of candidate compounds and novel AF formulations.

Ort, förlag, år, upplaga, sidor
2017. Vol. 33, nr 8, s. 613-623
Nyckelord [en]
abamectin, antifouling assay, Balanus (Amphibalanus) improvisus, copper, low-release/emission coatings, static vs flow-through
Nationell ämneskategori
Naturvetenskap
Identifikatorer
URN: urn:nbn:se:ri:diva-30820DOI: 10.1080/08927014.2017.1349897Scopus ID: 2-s2.0-85027128607OAI: oai:DiVA.org:ri-30820DiVA, id: diva2:1138630
Tillgänglig från: 2017-09-06 Skapad: 2017-09-06 Senast uppdaterad: 2019-02-05Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Personposter BETA

Berglin, MattiasPinori, Emiliano

Sök vidare i DiVA

Av författaren/redaktören
Berglin, MattiasPinori, Emiliano
Av organisationen
Kemi och material
I samma tidskrift
Biofouling (Print)
Naturvetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 82 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
v. 2.35.8