Air pollutant concentrations and atmospheric corrosion of organ pipes in European church environments
RISE., SP – Sveriges Tekniska Forskningsinstitut, SP Sveriges tekniska forskningsinstitut, YKI – Ytkemiska institutet.ORCID-id: 0000-0002-4037-3106
RISE., SP – Sveriges Tekniska Forskningsinstitut, SP Kemi Material och Ytor, Kemi.ORCID-id: 0000-0002-2754-2294
Vise andre og tillknytning
2008 (engelsk)Inngår i: Studies in Conservation, ISSN 0039-3630, E-ISSN 2047-0584, Vol. 53, nr 1, s. 24-40Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The atmospheric environment inside and outside historical organs in several European regions is reported. In each region, comparisons were made between an instrument suffering organ pipe corrosion and an organ without reported corrosion problems. Concentrations of acetic acid (ethanoic acid), formic acid (methanoic acid), acetaldehyde (ethanal), formaldehyde (methanal) and other volatile organic compounds in the organ environment were determined using active sampling. Temperature and relative humidity were recorded. In addition, polished metal samples that mimic the material used in the historical organ pipes have been exposed in the organ wind systemsfor up to 22 months. High concentrations of acetic acid andformic acid vapours are present in the wind system of the corroded organs. Acetaldehyde and formaldehyde are also present in smaller amounts. The main source of acetic acid is the wood from which the wind system is built. In contrast, formic acid is generated in the church environment outside the wind system. The results show that the two organic acids play an important role in the atmospheric corrosion of organ pipes. It is suggested that the corrosion of lead pipes in historical organs can be effectively reduced by removing the sources of gaseous acetic acid and formic acid in the wind system and in the church environment.

sted, utgiver, år, opplag, sider
2008. Vol. 53, nr 1, s. 24-40
HSV kategori
Identifikatorer
URN: urn:nbn:se:ri:diva-27494OAI: oai:DiVA.org:ri-27494DiVA, id: diva2:1054499
Merknad

A3552

Tilgjengelig fra: 2016-12-08 Laget: 2016-12-08 Sist oppdatert: 2024-07-04bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Person

Arrhenius, KarineRosell, Lars

Søk i DiVA

Av forfatter/redaktør
Arrhenius, KarineRosell, Lars
Av organisasjonen
I samme tidsskrift
Studies in Conservation

Søk utenfor DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric

urn-nbn
Totalt: 76 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
v. 2.45.0