Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Effects on protein adsorption, bacterial adhesion and contact angle of grafting PEG chains to polystyrene
RISE., SP – Sveriges Tekniska Forskningsinstitut, SP Sveriges tekniska forskningsinstitut, YKI – Ytkemiska institutet.
Visa övriga samt affilieringar
1993 (Engelska)Ingår i: Journal of Adhesion Science and Technology, ISSN 0169-4243, E-ISSN 1568-5616, Vol. 7, s. 503-517Artikel i tidskrift (Refereegranskat)
Abstract [en]

Poly(ethylene glycol) (PEG) has been grafted to polystyrene using branched poly(ethylene imine) (PEI) as an anchoring polymer. A dense grafting of PEG chains is obtained if a PEG-PEI adduct is first prepared by treatment of PEI with PEG epoxide and the adduct subsequently adsorbed on an oxidized polystyrene surface. Prepared in this way the PEG-PEI adduct is irreversibly attached to the surface with the PEG chains oriented towards the aqueous phase, as shown by ESCA and ellipsometry. This dense PEG coating is highly effective in preventing adsorption of fibrinogen and IgG, as well as adhesion of the oral bacterium Streptococcus mutans. Somewhat surprisingly, the degree of PEG branching, as well as the PEG molecular weight, did not markedly influence protein rejecting properties. The water contact angle on polystyrene decreased in the order: untreated polystyrene > oxidized > PEI treated > PEG-PEI treated. Block copolymers of poly(ethylene glycol)/poly(propylene glycol) type attached to polystyrene showed temperature dependent protein rejecting properties. At temperatures well below the cloud point of the polymer in water the surface is protein repellant whereas around and above the cloud point protein adsorption occurs to a considerable extent. The block copolymer layer expands and contracts with temperature variations, as can be monitored by ellipsometry.

Ort, förlag, år, upplaga, sidor
1993. Vol. 7, s. 503-517
Nyckelord [en]
Hydrophilization, polystyrene, protein adsorption, bacterial adhesion, PEG, ellipsometry, ESCA, contact angle
Nationell ämneskategori
Naturvetenskap
Identifikatorer
URN: urn:nbn:se:ri:diva-26605OAI: oai:DiVA.org:ri-26605DiVA, id: diva2:1053608
Anmärkning
A772Tillgänglig från: 2016-12-08 Skapad: 2016-12-08 Senast uppdaterad: 2020-12-01Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Av organisationen
YKI – Ytkemiska institutet
I samma tidskrift
Journal of Adhesion Science and Technology
Naturvetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 46 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf