Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Degree of conversion and flexural properties of a dendrimer/methyl methacrylate copolymer: Design of experiments and statistical screening
University of Turku.
University of Turku.
RISE, Swerea, Swerea SICOMP AB.
University of Turku.
2005 (Engelska)Ingår i: Dental Materials, ISSN 0109-5641, E-ISSN 1879-0097, Vol. 21, nr 2, s. 172-177Artikel i tidskrift (Refereegranskat)
Abstract [en]

Objectives: The aim of this study was to investigate the effect of photosensitive initiator and activator concentrations on the degree of conversion and flexural properties of an experimental photopolymerized dental copolymer containing dendrimer. Methods: The experimental resin system consisted of a dendrimer with 12 methacrylate groups and methyl methacrylate in a mass ratio of 80:20. The initiator and activator used were camphorquinone and 2-(N,N-dimethylamino)ethyl methacrylate, whose concentrations varied individually from 1 to 4wt%. The degree of conversion was determined with FTIR spectroscopy, and flexural strength and flexural modulus with the three-point bending test. The experiments were designed and analyzed, and the results plotted with Modde 5.0 software. Results: The highest degree of conversion was obtained with 2.5wt% initiator and activator concentrations, the highest flexural strength with 2.5wt% initiator and 1.0wt% activator concentration, and the highest flexural modulus with 1.0wt% initiator and activator concentrations. Significance: The results indicated that the degree of conversion increased, and flexural strength and flexural modulus decreased, with increasing initiator and activator concentrations. The high concentrations of initiator probably inhibited the transmittance of the active wavelengths to the depths of the samples (the inner filter effect), resulting in inhomogeneous conversion and thus decreased mechanical properties. © 2004 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Ort, förlag, år, upplaga, sidor
2005. Vol. 21, nr 2, s. 172-177
Nyckelord [en]
Biomaterials, Dendrimers, Dimethacrylates, Hyperbranched polymers, Methacrylates, Polymer materials, Polymer matrix, Statistical screening
Nationell ämneskategori
Materialteknik
Identifikatorer
URN: urn:nbn:se:ri:diva-13199DOI: 10.1016/j.dental.2003.12.005OAI: oai:DiVA.org:ri-13199DiVA, id: diva2:973395
Tillgänglig från: 2016-09-22 Skapad: 2016-09-22 Senast uppdaterad: 2017-11-21Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltexthttp://www.sciencedirect.com/science/article/pii/S0109564104000478
Av organisationen
Swerea SICOMP AB
I samma tidskrift
Dental Materials
Materialteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 56 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf