Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Long term stability and hysteresis effects in Pt100 sensors used in industry
RISE., SP – Sveriges Tekniska Forskningsinstitut, SP Mätteknik, Volym, flöde, temperatur o densitet.
RISE., SP – Sveriges Tekniska Forskningsinstitut, SP Mätteknik, Volym, flöde, temperatur o densitet.
RISE., SP – Sveriges Tekniska Forskningsinstitut, SP Mätteknik, Volym, flöde, temperatur o densitet.
RISE., SP – Sveriges Tekniska Forskningsinstitut, SP Mätteknik, Volym, flöde, temperatur o densitet.
2013 (Engelska)Ingår i: AIP Conference Proceedings 9th International Temperature Symposium on Temperature (ISSN: 0094-243X), 2013, Vol. 1152, s. 421-426s. 421-426Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

A Pt100 sensor is under normal conditions a very accurate and stable sensor for temperature measurements. Two important factors that can have influence on the results are its drift during time and the hysteresis effect at temperature changes. Different types of Pt100 sensors will show varying sensitivity for these effects. This study includes a number of partially supported wire type Pt100 sensors mainly used as reference sensors at different industries and laboratories. For most of the sensors, there is a history of calibration data for several years. By using a dry block calibrator, the hysteresis effects of the sensors are measured in the temperature range 0 °C up to 500 °C, depending on the calibration range of the sensor. The suitability of the method is evaluated by measurements of the stability of the dry-block and the repeatability of hysteresis tests. The evaluation shows that it is possible to measure hysteresis effects above a few mK. The tested Pt100 sensors exhibits hysteresis effects of 20 mK peak-to-peak as most, which is in the same magnitude as the uncertainty of the calibration and also more significant than the annual drift. The best sensors showed a hysteresis of just a few mK.

Ort, förlag, år, upplaga, sidor
2013. Vol. 1152, s. 421-426s. 421-426
Nyckelord [en]
Dry block calibrator, Hysteresis, Industrial platinum resistance thermometer
Nationell ämneskategori
Naturvetenskap
Identifikatorer
URN: urn:nbn:se:ri:diva-12486DOI: 10.1063/1.4819578Scopus ID: 2-s2.0-84884997560Lokalt ID: 23842OAI: oai:DiVA.org:ri-12486DiVA, id: diva2:970310
Konferens
9th International Temperature Symposium on Temperature: Its Measurement and Control in Science and Industry, ITS 2012; Los Angeles, CA; United States; 19-23 Mar., 2012
Tillgänglig från: 2016-09-13 Skapad: 2016-09-13 Senast uppdaterad: 2020-12-01Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus
Av organisationen
Volym, flöde, temperatur o densitet
Naturvetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 342 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf