The reduced cross-section method for evaluation of the fire resistance of timber members: Discussion and determination of the zero-strength layer
RISE., SP – Sveriges Tekniska Forskningsinstitut, SP Hållbar Samhällsbyggnad.
RISE., SP – Sveriges Tekniska Forskningsinstitut, SP Hållbar Samhällsbyggnad. Tallinn University of Technology, Estonia.ORCID-id: 0000-0002-8001-401x
ETH Zurich, Switzerland.
University of Sassari, Italy.
2015 (Engelska)Ingår i: Fire technology, ISSN 0015-2684, E-ISSN 1572-8099, Vol. 51, nr 6, s. 1285-1309Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The reduced cross-section method (RCSM) is included in Eurocode 5 (EN-1995-1-2) for the design of timber members in fire conditions. The method considers the strength and stiffness reduction beneath the charred layer by adding an additional depth (known as the ‘zero-strength’ layer) to the charring depth. The zero-strength layer is one of the key parameters for the fire design of timber members. Recently, some concerns have been raised that the zero-strength layer might be non-conservative in some applications. This paper presents the background to the RCSM, followed by a short discussion on the mechanical assumptions, simplifications and possible limitations of the method itself. Further, it discusses determination of the zero-strength layer thickness for members in bending, tension and compression, and provides guidelines on the use of standard experimental tests to determine this quantity. For demonstration of the determination procedure, the results of fire tests in bending, tension and compression were analysed following the described procedure. Results show that the zero-strength layer exceeds the value used in practice, indicate that the method of Eurocode 5 may be non-conservative and should be revised.

Ort, förlag, år, upplaga, sidor
2015. Vol. 51, nr 6, s. 1285-1309
Nyckelord [en]
Timber, Fire design, Zero-strength layer, Reduced, Cross-Section Method, Fire testing, Advanced calculation
Nationell ämneskategori
Naturvetenskap
Identifikatorer
URN: urn:nbn:se:ri:diva-6871DOI: 10.1007/s10694-014-0421-6Scopus ID: 2-s2.0-84945189214Lokalt ID: 29383OAI: oai:DiVA.org:ri-6871DiVA, id: diva2:964712
Tillgänglig från: 2016-09-08 Skapad: 2016-09-08 Senast uppdaterad: 2023-05-08Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Just, Alar

Sök vidare i DiVA

Av författaren/redaktören
Just, Alar
Av organisationen
SP Hållbar Samhällsbyggnad
I samma tidskrift
Fire technology
Naturvetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 69 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf