Investigation of the Equivalence of National Dew-Point Temperature Realizations in the -50 C to + 20 C Range
MIKES, Finland.
Hellenic Institute of Metrology, Greece.
NPL National Physical Laboratory, United Kingdom.
NPL National Physical Laboratory, United Kingdom.
Visa övriga samt affilieringar
2012 (Engelska)Ingår i: International journal of thermophysics, ISSN 0195-928X, E-ISSN 1572-9567, Vol. 33, nr 8-9, s. 1422-1437Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

In the field of humidity quantities, the first CIPM key comparison, CCT-K6 is at its end. The corresponding European regional key comparison, EUROMET.T-K6, was completed in early 2008, about 4 years after the starting initial measurements in the project. In total, 24 NMIs from different countries took part in the comparison. This number includes 22 EURAMET countries, and Russia and South Africa. The comparison covered the dew-point temperature range from -50 C to +20 C. It was carried out in three parallel loops, each with two chilled mirror hygrometers as transfer standards in each loop. The comparison scheme was designed to ensure high quality results with evenly spread workload for the participants. It is shown that the standard uncertainty due to the long-term instability was smaller than 0.008 C in all loops. The standard uncertainties due to links between the loops were found to be smaller than 0.025 C at -50 C and 0.010 C elsewhere. Conclusions on the equivalence of the dew-point temperature standards are drawn on the basis of calculated bilateral degrees of equivalence and deviations from the EURAMET comparison reference values (ERV). Taking into account 16 different primary dew-point realizations and 8 secondary realizations, the results demonstrate the equivalence of a large number of laboratories at an uncertainty level that is better than achieved in other multilateral comparisons so far in the humidity field.

Ort, förlag, år, upplaga, sidor
2012. Vol. 33, nr 8-9, s. 1422-1437
Nyckelord [en]
Degrees of equivalence, Dew-point temperature, Key comparison
Nationell ämneskategori
Naturvetenskap
Identifikatorer
URN: urn:nbn:se:ri:diva-6419DOI: 10.1007/s10765-011-0950-xScopus ID: 2-s2.0-84879605370Lokalt ID: 23961OAI: oai:DiVA.org:ri-6419DiVA, id: diva2:964257
Tillgänglig från: 2016-09-08 Skapad: 2016-09-08 Senast uppdaterad: 2021-01-12Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus
Av organisationen
SP – Sveriges Tekniska Forskningsinstitut / Klimatsimulering (ETks )
I samma tidskrift
International journal of thermophysics
Naturvetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 53 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf