Comparison of Blackbody Sources for Low-Temperature IR Calibration
RISE., SP – Sveriges Tekniska Forskningsinstitut, SP Mätteknik, Volym, flöde, temperatur o densitet.
RISE., SP – Sveriges Tekniska Forskningsinstitut, SP Mätteknik, Volym, flöde, temperatur o densitet.
RISE., SP – Sveriges Tekniska Forskningsinstitut, SP Mätteknik, Volym, flöde, temperatur o densitet.
2015 (Engelska)Ingår i: International Journal of Thermophysics, Vol. 36, nr 12, s. 3310-3319Artikel i tidskrift (Övrigt vetenskapligt) Published
Abstract [en]

Radiation thermometers are traditionally mostly used in high-temperature applications. They are, however, becoming more common in different applications at room temperature or below, in applications such as monitoring frozen food and evaluating heat leakage in buildings. To measure temperature accurately with a pyrometer, calibration is essential. A problem with traditional, commercially available, blackbody sources is that ice is often formed on the surface when measuring temperatures below \(0\,{}^{\circ }\hbox {C}\). This is due to the humidity of the surrounding air and, as ice does not have the same emissivity as the blackbody source, it biases the measurements. An alternative to a traditional blackbody source has been tested by SP Technical Research Institute of Sweden. The objective is to find a cost-efficient method of calibrating pyrometers by comparison at the level of accuracy required for the intended use. A disc-shaped blackbody with a surface pyramid pattern is placed in a climatic chamber with an opening for field of view of the pyrometer. The temperature of the climatic chamber is measured with two platinum resistance thermometers in the air in the vicinity of the disc. As a rule, frost will form only if the deposition surface is colder than the surrounding air, and, as this is not the case when the air of the climatic chamber is cooled, there should be no frost or ice formed on the blackbody surface. To test the disc-shaped blackbody source, a blackbody cavity immersed in a conventional stirred liquid bath was used as a reference blackbody source. Two different pyrometers were calibrated by comparison using the two different blackbody sources, and the results were compared. The results of the measurements show that the disc works as intended and is suitable as a blackbody radiation source.

Ort, förlag, år, upplaga, sidor
2015. Vol. 36, nr 12, s. 3310-3319
Nationell ämneskategori
Naturvetenskap
Identifikatorer
URN: urn:nbn:se:ri:diva-5670Lokalt ID: 30669OAI: oai:DiVA.org:ri-5670DiVA, id: diva2:963501
Tillgänglig från: 2016-09-08 Skapad: 2016-09-08 Senast uppdaterad: 2020-12-01Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Av organisationen
Volym, flöde, temperatur o densitet
Naturvetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 44 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf