Fire spread in a large compartment with exposed cross-laminated timber and open ventilation conditions: #FRIC-02 - Exposed wall and ceiling
RISE Research Institutes of Sweden, Säkerhet och transport, Brand och Säkerhet. NTNU, Norway.ORCID-id: 0000-0003-2396-1325
SINTEF, Norway.
RISE Research Institutes of Sweden, Säkerhet och transport, Brand och Säkerhet.ORCID-id: 0000-0002-7663-1525
RISE Research Institutes of Sweden, Säkerhet och transport, Brand och Säkerhet. NTNU, Norway.ORCID-id: 0000-0002-4831-7563
Visa övriga samt affilieringar
2023 (Engelska)Ingår i: Fire safety journal, ISSN 0379-7112, E-ISSN 1873-7226, Vol. 141, artikel-id 103986Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Cross-laminated timber (CLT) is becoming increasingly popular due to its many advantages. However, it has been shown that exposed CLT can have a significant effect on fire dynamics and spread rates. Further studies are therefore needed to better understand the impact of CLT to fire safety. Two large-scale CLT compartment fire experiments (95 m2) representing a modern office building have been performed, #FRIC-01 and #FRIC-02. This paper presents the second experiment, #FRIC-02, with exposed CLT on the back wall and the ceiling. The fire developed fast and spread across the room in less than 3.5 min from ignition of the wood crib on the floor and in 1.5 min after the ignition of the ceiling. Large external flames were observed, despite the compartment being well-ventilated. The 5-layer CLT, which comprised a 40 mm thick exposed outer layer and was face-bonded using a common European polyurethane adhesive, exhibited glue-line integrity failure and led to a second flashover after a significant period of decay. Subsequent layers of 20 mm also delaminated before the fire was manually extinguished after 3 h. Compared to #FRIC-01, the fire spread rate was faster, and temperatures, charring rates, heat release rates and external flames were higher. 

Ort, förlag, år, upplaga, sidor
Elsevier Ltd , 2023. Vol. 141, artikel-id 103986
Nyckelord [en]
Adhesives; Ceilings; Flashover; Laminating; Office buildings; Timber; Walls (structural partitions); Compartment fires; Condition; Cross laminated; Cross-laminated timber; External flame; Facade fire; Fire spread; Laminated timber; Large-scales; Second flashover; Fires
Nationell ämneskategori
Samhällsbyggnadsteknik
Identifikatorer
URN: urn:nbn:se:ri:diva-67660DOI: 10.1016/j.firesaf.2023.103986Scopus ID: 2-s2.0-85173336165OAI: oai:DiVA.org:ri-67660DiVA, id: diva2:1815503
Anmärkning

The authors gratefully acknowledge the financial support by the Research Council of Norway through the program BRANNSIKKERHET, project number 294649, and by partners of the research centre FRIC.

Tillgänglig från: 2023-11-29 Skapad: 2023-11-29 Senast uppdaterad: 2024-04-09Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Sæter Bøe, AndreasBrandon, DanielSteen-Hansen, Anne

Sök vidare i DiVA

Av författaren/redaktören
Sæter Bøe, AndreasBrandon, DanielSteen-Hansen, Anne
Av organisationen
Brand och Säkerhet
I samma tidskrift
Fire safety journal
Samhällsbyggnadsteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 34 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf