Can particle counting replace conventional surveillance for airborne bacterial contamination assessments?: A systematic review using narrative synthesis
University of Gothenburg, Sweden.
University of Gothenburg, Sweden.
RISE Research Institutes of Sweden, Material och produktion, Metodik för produktframtagning.ORCID-id: 0000-0002-3034-6745
University of Gothenburg, Sweden.
Visa övriga samt affilieringar
2023 (Engelska)Ingår i: American Journal of Infection Control, ISSN 0196-6553, E-ISSN 1527-3296, Vol. 51, nr 12, s. 1417-Artikel, forskningsöversikt (Refereegranskat) Published
Abstract [en]

Background: Bacterial airborne contamination in the operating room during surgery indicates an increased risk for surgical site infection. The conventional surveillance method for bacteria in the air is by air sampling, plating, and counting of colony-forming units (CFU). Particle counting measures particles in the air, typically in sizes of 1-20 µm, and has been suggested as an alternative to CFU measurements. The primary aim was to investigate the correlation between the number of airborne CFU and particles during surgery. The secondary aim was to explore whether different ventilation settings influence the correlation between CFU and particles. Methods: The databases Cochrane, Embase, and Medline were searched for relevant publications. Due to the heterogeneity of the data, meta-analysis was not possible and a narrative analysis was performed instead. Results: The review included 11 studies. Two of the studies (n = 2) reported strong correlation between particles and CFU (Rp = 0.76 and Rc = 0.74). The remaining studies observed moderate correlation (n = 3), low correlation (n = 3), or no correlation (n = 3). Based on the primary results from this study, ventilation attribution to distinguish the correlation between particles and CFU had no or little contribution. Conclusions: Due to the lack of convincing evidence of correlation and lack of high-quality studies performing measurements in a standardized way, the studies could not provide the necessary evidence that show that particle counting could be used as a substitution for conventional air bacterial assessment. Further studies are warranted to strengthen the conclusion. © 2023 The Authors

Ort, förlag, år, upplaga, sidor
Elsevier Inc. , 2023. Vol. 51, nr 12, s. 1417-
Nyckelord [en]
Air quality, Air sampling, Colony forming units, Microbial contamination, Operating room
Nationell ämneskategori
Arbetsmedicin och miljömedicin
Identifikatorer
URN: urn:nbn:se:ri:diva-65601DOI: 10.1016/j.ajic.2023.05.004Scopus ID: 2-s2.0-85162128032OAI: oai:DiVA.org:ri-65601DiVA, id: diva2:1777547
Tillgänglig från: 2023-06-29 Skapad: 2023-06-29 Senast uppdaterad: 2024-06-07Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Björn, Camilla

Sök vidare i DiVA

Av författaren/redaktören
Björn, Camilla
Av organisationen
Metodik för produktframtagning
I samma tidskrift
American Journal of Infection Control
Arbetsmedicin och miljömedicin

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 19 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf