Effects of lung tissue characterization in radiotherapy of breast cancer under deep inspiration breath hold when using Monte Carlo dosimetry
RISE Research Institutes of Sweden. University of Gothenburg, Sweden.ORCID-id: 0000-0001-7250-1443
Sahlgrenska University Hospital, Sweden.
Sahlgrenska University Hospital, Sweden.
University of Gothenburg, Sweden; Sahlgrenska University Hospital, Sweden.
Visa övriga samt affilieringar
2021 (Engelska)Ingår i: Physica medica (Testo stampato), ISSN 1120-1797, E-ISSN 1724-191X, Vol. 90, s. 83-90Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Purpose: To investigate the sensitivity of Monte Carlo (MC) calculated lung dose distributions to lung tissue characterization in external beam radiotherapy of breast cancer under Deep Inspiration Breath Hold (DIBH). Methods: EGSnrc based MC software was employed. Mean lung densities for one hundred patients were analysed. CT number frequency and clinical dose distributions were calculated for 15 patients with mean lung density below 0.14 g/cm3. Lung volume with a pre-defined CT numbers was also considered. Lung tissue was characterized by applying different CT calibrations in the low-density region and air-lung tissue thresholds. Dose impact was estimated by Dose Volume Histogram (DVH) parameters. Results: Mean lung densities below 0.14 g/cm3 were found in 10% of the patients. CT numbers below −960 HU dominated the CT frequency distributions with a high rate of CT numbers at −990 HU. Mass density conversion approach influenced the DVH shape. V4Gy and V8Gy varied by 7% and 5% for the selected patients and by 9% and 3.5% for the pre-defined lung volume. V16Gy and V20Gy, were within 2.5%. Regions above 20 Gy were affected. Variations in air- lung tissue differentiation resulted in DVH parameters within 1%. Threshold at −990 HU was confirmed by the CT number frequency distributions. Conclusions: Lung dose distributions were more sensitive to variations in the CT calibration curve below lung (inhale) density than to air-lung tissue differentiation. Low dose regions were mostly affected. The dosimetry effects were found to be potentially important to 10% of the patients treated under DIBH.

Ort, förlag, år, upplaga, sidor
Associazione Italiana di Fisica Medica , 2021. Vol. 90, s. 83-90
Nyckelord [en]
Absorbed dose, Breast cancer radiotherapy, DIBH, Lung tissue characterization, Monte Carlo simulations, Article, breast cancer, breath holding, cancer radiotherapy, computer assisted tomography, deep inspiration breath hold, dose volume histogram, dosimetry, external beam radiotherapy, human, inspiratory capacity, lung parenchyma, lung volume, major clinical study, patient selection, radiation dose distribution, respiratory airflow, tissue characterization
Nationell ämneskategori
Cancer och onkologi
Identifikatorer
URN: urn:nbn:se:ri:diva-56926DOI: 10.1016/j.ejmp.2021.09.009Scopus ID: 2-s2.0-85115614148OAI: oai:DiVA.org:ri-56926DiVA, id: diva2:1613301
Anmärkning

Funding details: Västra Götalandsregionen; Funding details: Strålsäkerhetsmyndigheten, SSM; Funding text 1: Financial support of King Gustav the V Jubilee Clinic Foundation, The Swedish Radiation Safety Authority and The Healthcare Committee, Region Västra Götaland are greatly acknowledged.

Tillgänglig från: 2021-11-22 Skapad: 2021-11-22 Senast uppdaterad: 2022-01-20Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Andersson, Patrik

Sök vidare i DiVA

Av författaren/redaktören
Andersson, Patrik
Av organisationen
RISE Research Institutes of Sweden
I samma tidskrift
Physica medica (Testo stampato)
Cancer och onkologi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 23 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf