Insulation Design of a Medium Frequency Power Transformer for a Cost-Effective Series High Voltage DC Collection Network of an Offshore Wind Farm
RISE - Research Institutes of Sweden, Säkerhet och transport, Mätteknik.ORCID-id: 0000-0002-0294-4430
University of Zanjan, Iran.
Chalmers University of Technology, Sweden.
2019 (Engelska)Ingår i: Proceedings of the 21st International Symposium on High Voltage Engineering, Switzerland: Springer Publishing Company, 2019, s. 06-1417Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

DC can be used advantageously in transmission of power from offshore wind farms, utilizing series connection of the individual turbines’ outputs. Employing individual wind turbine converters, operating at high frequency, the advantage of DC can be achieved without the need for a large central converter. This solution obviates the need of expensive, bulky and heavy 50 Hz transformer or centralized DC/DC converter platforms.

Power electronic converters are among the enabling technologies to establish a series DC intertie system. The most important advantage of a DC/DC converter using a Medium Frequency Power Transformer (MFPT) is its compact size in comparison with a normal grid frequency transformer.

The function of a MFPT is to provide voltage step up and isolation between generators and the HVDC link. The need for a compact structure dictates further design constraints. A MFPT should have a high-power transmission capability from a small volume as well as minimal internal insolation distances. Furthermore, in the series DC integration circuit, DC/DC converters can experience a very high offset DC voltage depending on the converter’s position with respect to earth (in the range of one or two hundred kilovolts), while the primary side (wind turbine generator side) is only exposed to a few kV.

Due to its promising features, many research activities have been devoted to the design and optimization of MFPTs. However, only a few activities specifically addressed the insulation requirements for them.

Ort, förlag, år, upplaga, sidor
Switzerland: Springer Publishing Company, 2019. s. 06-1417
Nyckelord [en]
HVDC transformer, Medium frequency power transformer, Power transformer insulation design, High-power.DC/DC converter, Oil-paper barrier insulation system
Nationell ämneskategori
Annan elektroteknik och elektronik
Identifikatorer
URN: urn:nbn:se:ri:diva-40594DOI: 10.1007/978-3-030-31680-8_134ISBN: 978-3-030-31679-2 (tryckt)OAI: oai:DiVA.org:ri-40594DiVA, id: diva2:1367146
Konferens
The International Symposium on High Voltage Engineering 2019.
Tillgänglig från: 2019-11-01 Skapad: 2019-11-01 Senast uppdaterad: 2023-05-26Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Person

Kharezy, Mohammad

Sök vidare i DiVA

Av författaren/redaktören
Kharezy, Mohammad
Av organisationen
Mätteknik
Annan elektroteknik och elektronik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetricpoäng

doi
isbn
urn-nbn
Totalt: 142 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf