Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Real-time monitoring of indoor air corrosivity in cultural heritage institutions with metallic electrical resistance sensors
RISE - Research Institutes of Sweden (2017-2019), Material och produktion, KIMAB. (Institut de la Corrosion)
Institute of Chemical Technology, Czech Republic.
Centre de Recherche et de Restauration des Musees de France, France.
National Museum of Denmark, Denmark.
Visa övriga samt affilieringar
2013 (Engelska)Ingår i: Studies in Conservation, ISSN 0039-3630, E-ISSN 2047-0584, Vol. 58, nr 2, s. 117-128Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

A system for continuous monitoring of atmospheric corrosivity has been developed. An electronic unit measures and records changes in the electrical resistance of a thin metal track applied on an insulating substrate. If the metal corrodes, the effective cross sectional area of the track decreases and the electrical resistance increases. Sensors made of silver, copper, iron/steel, zinc, lead, tin, aluminium, bronze, and brass at thicknesses from 50 nm to 250 μm were tailored for environments with different corrosivities. The developed technology proved capable of providing high sensitivity, allowing for real-time corrosion monitoring even in low-corrosive indoor cultural heritage facilities. Laboratory tests showed good reproducibility with the standard deviation of parallel measurements at less than ±20% for metals which corrode uniformly in the tested environments. Several examples selected from a broad testing programme in partner museums, libraries, and other institutions show successful applications of the logger system for characterization of air quality control in indoor locations, during transport and in temporary exhibitions; assessment of new buildings and storage facilities; and fundamental studies of optimal conservation and storage procedures. A first outline of a classification system for lead, which is particularly sensitive to the presence of carboxylic acids, is given. The technique has a large potential as an independent method for monitoring air quality in facilities displaying and storing valuable objects of cultural heritage.

Ort, förlag, år, upplaga, sidor
2013. Vol. 58, nr 2, s. 117-128
Nyckelord [en]
Air quality control, Copper, Material degradation, Metal corrosion, Reactive monitoring, Silver, Atmospheric corrosivity, Continuous monitoring, Electrical resistance sensors, Electrical resistances, Insulating substrates, Real time corrosion monitoring, Air quality, Corrosion, Historic preservation, Quality control, Sensors, Electric resistance
Nationell ämneskategori
Teknik och teknologier
Identifikatorer
URN: urn:nbn:se:ri:diva-40408DOI: 10.1179/2047058412Y.0000000080Scopus ID: 2-s2.0-84877880576OAI: oai:DiVA.org:ri-40408DiVA, id: diva2:1361456
Tillgänglig från: 2019-10-16 Skapad: 2019-10-16 Senast uppdaterad: 2023-05-16Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Thierry, Dominique

Sök vidare i DiVA

Av författaren/redaktören
Thierry, Dominique
Av organisationen
KIMAB
I samma tidskrift
Studies in Conservation
Teknik och teknologier

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 18 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf