Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
A Comprehensive Model of Data Center: From CPU to Cooling Tower
Luleå University of Technology, Sweden.
RISE - Research Institutes of Sweden (2017-2019), ICT, SICS.ORCID-id: 0000-0001-7381-9154
National Institute of Applied Sciences, France.
Luleå University of Technology, Sweden.
Visa övriga samt affilieringar
2018 (Engelska)Ingår i: IEEE Access, E-ISSN 2169-3536, Vol. 6, s. 61254-61266, artikel-id 8489849Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Aiming at addressing environmental challenges, large data centers, such as Facebook, Google, and Yahoo, are increasing share of green power in their daily energy consumption. Such trends drive research into new directions, e.g., sustainable data centers. The research often relies on expressive models that provide sufficient details, however, practical to re-use and expand. There is a lack of available data center models that capture internal operating states of the facility from the CPU to the cooling tower. It is a challenge to develop a model that allows to describe complete data center of any scale including its connection to the grid. This paper proposes such a model building on the existing work. The challenge was to put the pieces of data center together and model behavior of each element so that interdependencies between components and parameters and operating states are captured correctly and in sufficient details. The proposed model was used in the project 'Data center microgrid integration' and proven to be adequate and important to support such study.

Ort, förlag, år, upplaga, sidor
2018. Vol. 6, s. 61254-61266, artikel-id 8489849
Nyckelord [en]
chiller, cooling, cooling tower, CRAH, Data center, microgrid, model, server, smart grid, Cooling towers, Digital storage, Energy utilization, Models, Servers, Data centers, Micro grid, Green computing
Nationell ämneskategori
Naturvetenskap
Identifikatorer
URN: urn:nbn:se:ri:diva-36933DOI: 10.1109/ACCESS.2018.2875623Scopus ID: 2-s2.0-85054609232OAI: oai:DiVA.org:ri-36933DiVA, id: diva2:1274184
Anmärkning

 Funding details: Energimyndigheten, 2016-007959; Funding details: Energimyndigheten, 2016-00717;

Tillgänglig från: 2018-12-28 Skapad: 2018-12-28 Senast uppdaterad: 2023-05-25Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Vesterlund, Mattias

Sök vidare i DiVA

Av författaren/redaktören
Vesterlund, Mattias
Av organisationen
SICS
I samma tidskrift
IEEE Access
Naturvetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 75 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf