Proficiency testing for conducted immunity with a new round robin test deviceVisa övriga samt affilieringar
2016 (Engelska)Ingår i: 2016 International Symposium on Electromagnetic Compatibility - EMC EUROPE, 2016, s. 274-279, artikel-id 7739174Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]
Last year, a new round robin test device was proposed for inter-laboratory comparisons in conducted immunity testing according to IEC 61000-4-6[1]. The device has recently been successfully evaluated among all EMRP Project partners. The device is able to confirm or to deny the testing capability of a laboratory by recording a full set of parameters. The device is now ready for deployment as the first commercial proficiency testing device for conducted immunity.
Ort, förlag, år, upplaga, sidor
2016. s. 274-279, artikel-id 7739174
Nyckelord [en]
Auxiliary Equipment (AE), common mode, conducted immunity, Coupling-Decoupling Network (CDN), disturbance signal, Electromagnetic Compatibility (EMC), EN ISO 17025, EN ISO 17043, Equipment under Test (EUT), IEC 61000-4-6, inter-laboratory comparison, proficiency testing, round robin, test device, Auxiliary equipment, Equipment testing, Routers, Superconducting tapes, Decoupling network, Disturbance signals, Equipment under tests, Interlaboratory comparison, ISO 17025, Electromagnetic compatibility
Nationell ämneskategori
Annan elektroteknik och elektronik
Identifikatorer
URN: urn:nbn:se:ri:diva-27589DOI: 10.1109/EMCEurope.2016.7739174Scopus ID: 2-s2.0-85001129175ISBN: 978-1-5090-1416-3 (digital)OAI: oai:DiVA.org:ri-27589DiVA, id: diva2:1057886
Konferens
2016 International Symposium on Electromagnetic Compatibility (EMC EUROPE), September 5-9, 2016, Wroclaw, Poland
Anmärkning
References: Tas, E., Pythoud, F., A new conducted immunity test device for interlaboratory comparisons (2015) IEEE International Symposium on Electromagnetic Compatibility and EMC Europe; (2005) ISO/IEC 17025: General Requirements for the Competence of Testing and Calibration Laboratories, , 2nd Edition; (2010) ISO/IEC 17043: Conformity Assesment-General Requirements for Proficiency Testing, , 1st Edition; Goedbloed, J.J., Beeckman, P.A., Uncertainty of the CISPR/A radiated emission round-robin test results (2004) IEEE Transactions on Electromagnetic Compatibility, 46 (2). , May; (2013) IEC 61000-4-6 Electromagnetic Compatibility (EMC)-Part 4-6: Testing and Measurement Techniques-Immunity to Conducted Disturbances, Induced by Radio-frequency Fields, , 4th Edition, IEC
2016-12-192016-12-192020-12-01Bibliografiskt granskad