Control of wire rod temperature with water cooling
RISE, Swerea, Swerea MEFOS AB.
1993 (engelsk)Inngår i: Mechanical Working and Steel Processing Conference Proceedings, Publ by Iron & Steel Soc of AIME, Warrendale, PA, United States , 1993, Vol. 31, s. 413-419Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

Temperature control is very important in wire rod production. A short rapid water cooling equipment for wire rod has been studied in pilot-plant trials at MEFOS. The equipment is mainly a water filled tube, fed by a housing with a circumferential nozzle. Cooling experiments were done with 25 mm C-Mn steel bars rolled to 19 mm bars. The cooling equipment diameters were 25 mm and 30 mm. The decrease in temperature was measured as well as feeding water pressure in the housing and water pressure in the cooling tube. The heating temperature, rolling speed, cooling tube length and water pressure were changed for the 25 mm equipment. Temperature difference between head and tail ends of the bar was also studied for the 25 mm equipment. Nozzle gap, tube length and water pressure were changed for the 30 mm equipment. A statistical analysis of the cooling results for the 25 mm equipment showed that the cooling was dependent on the water pressure, rolling speed and the furnace temperature. A change in water pressure from 1.4 to 22.8 bar increased the cooling 90 °C. The temperature difference between the ends of the bar was only influenced by the initial temperature difference and the bar temperature. The results from experiments with 30 mm equipment showed no effect on nozzle gap and tube length. The cooling effect of 30 mm equipment at pressures from 2.5 to 5 bar is similar to 25 mm equipment. The variation of cooling with pressure is higher compared with 25 mm equipment. The water consumption in a 30 mm equipment is twice the consumption in a 25 mm equipment at the same pressure.

sted, utgiver, år, opplag, sider
Publ by Iron & Steel Soc of AIME, Warrendale, PA, United States , 1993. Vol. 31, s. 413-419
Serie
Mechanical working and steel processing, ISSN 0147-7781
HSV kategori
Identifikatorer
URN: urn:nbn:se:ri:diva-13516Scopus ID: 2-s2.0-0027807641ISBN: 932897878 (tryckt)OAI: oai:DiVA.org:ri-13516DiVA, id: diva2:973725
Konferanse
Proceedings of the 35th Mechanical Working and Steel Processing Conference
Tilgjengelig fra: 2016-09-22 Laget: 2016-09-22bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Scopushttp://www.scopus.com/inward/record.url?eid=2-s2.0-0027807641&partnerID=40&md5=82ad8a8c0511b7fe9008a8f313ac3c94
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

isbn
urn-nbn

Altmetric

isbn
urn-nbn
Totalt: 27 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
v. 2.43.0