Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
The impact of surface roughness and permeability in hydroxyapatite bone regeneration membranes
Malmö University, Sweden; Region Halland, Sweden.
Malmö University, Sweden.
Region Halland, Sweden.
RISE - Research Institutes of Sweden, Material och produktion, IVF.ORCID-id: 0000-0003-4860-8763
Vise andre og tillknytning
2015 (engelsk)Inngår i: Clinical Oral Implants Research, ISSN 0905-7161, E-ISSN 1600-0501, Vol. 27, nr 8, s. 1047-1054Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Background: One of the crucial aspects in guided bone regeneration is the space maintenance. This is normally created by a membrane, which should primarily be accepted by the surrounding tissues without causing any adverse reactions. The impact of surface topography, biological acceptance as well as permeability of these membranes has been carefully discussed in the literature. Purpose: The purpose of this study was to evaluate histologically the bone forming properties inside of hollow hydroxyapatite space-maintaining devices with different inner surfaces and different permeabilities in an animal calvaria model in vivo. Materials and methods: A total of 36 hollow domes with three different designs made of hydroxyapatite were surgically attached to the skulls of rabbits. Group 1 had a moderately rough inner surface. Group 2 had a smooth inner surface. Group 3 had the same properties as Group 1 but had macroscopic holes on the top. The domes were left to heal for 12 weeks and were then processed for undecalcified ground sectioning. Histological evaluations were performed using a light microscope and scanning electron microscopy. The bone-implant contact (BIC) percentage along the device was calculated. Results: The median percentage of BIC was higher for Group 1 compared with Group 2 (P = 0.004). Group 1 produced a larger median BIC compared with Group 3 (P < 0.0001). Conclusions: Within the limits of this preclinical study, these findings suggest that a moderately rough inner surface of a ceramic membrane along with a non-permeable device produces more bone than a smooth inner surface.

sted, utgiver, år, opplag, sider
Blackwell Munksgaard , 2015. Vol. 27, nr 8, s. 1047-1054
Emneord [en]
Animal experiments, Biomaterials, Bone regeneration, Guided tissue regeneration, Surface chemistry
HSV kategori
Identifikatorer
URN: urn:nbn:se:ri:diva-13300DOI: 10.1111/clr.12717Scopus ID: 2-s2.0-84946206475OAI: oai:DiVA.org:ri-13300DiVA, id: diva2:973506
Tilgjengelig fra: 2016-09-22 Laget: 2016-09-22 Sist oppdatert: 2019-07-09bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopushttp://onlinelibrary.wiley.com/doi/10.1111/clr.12717/abstract

Personposter BETA

Adolfsson, Erik

Søk i DiVA

Av forfatter/redaktør
Adolfsson, Erik
Av organisasjonen
I samme tidsskrift
Clinical Oral Implants Research

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 60 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
v. 2.35.9