The reduced cross section method applied to glulam timber exposed to non-standard fire curves
RISE., SP – Sveriges Tekniska Forskningsinstitut, SP Fire Research.
RISE., SP – Sveriges Tekniska Forskningsinstitut, SP Hållbar Samhällsbyggnad.
RISE., SP – Sveriges Tekniska Forskningsinstitut.
2015 (engelsk)Inngår i: Fire technology, ISSN 0015-2684, E-ISSN 1572-8099, Vol. 51, nr 6, s. 1311-1340Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Timber is an desired material for structural applications due to its green credentials and attractive external appearance. Fire safety design of timber structures is largely limited to considering the exposure of elements to the standard fire, to which timber demonstrates exceptional resilience. This paper reports on a series of tests which were carried out with the intention of exploring the impact of non-standard fires on timber elements. Because of the natural variation in timber elements, the tests and the resulting analysis of the test results were conceived and designed in such a way that as much information about the statistical distribution of the response of the elements as possible could be obtained. The resulting testing programme comprised four furnace fire tests, each of eight loaded timber beams, with three different temperature time curves: two standard fire tests, one long-cool parametric fire and one short-hot parametric fire. The reduced cross section method for structural calculations is extended in this paper to parametric fire exposures, and the results of the tests are compared with this method. It is shown that the thickness of the zero-strength layer is dependent on the temperature time curve to which the timber is exposed in the furnace and that the 7 mm zero-strength layer prescribed in EN 1995-1-2 may be un-conservative for members in bending. For the cases studied, the zero-strength layer thickness in bending is shown to be around about 15 mm under standard fire exposure and 16 mm under exposure to a long cool parametric fire. Conversely, the zero-strength layer is only 8 mm deep under exposure to a short hot parametric fire. This has implications for the design of timber elements not only for parametric fire exposure in enclosures, but also perhaps for the use of timber elements in large open structures such as halls or arenas where more localised fire exposure or travelling fire exposure may be expected.

sted, utgiver, år, opplag, sider
2015. Vol. 51, nr 6, s. 1311-1340
Emneord [en]
Timber in fire, Reduced cross section method, Parametric fires, Performance based design, Glulam beams
HSV kategori
Identifikatorer
URN: urn:nbn:se:ri:diva-6870DOI: 10.1007/s10694-015-0485-yLokal ID: 29382OAI: oai:DiVA.org:ri-6870DiVA, id: diva2:964711
Tilgjengelig fra: 2016-09-08 Laget: 2016-09-08 Sist oppdatert: 2019-07-09bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Personposter BETA

Lange, David

Søk i DiVA

Av forfatter/redaktør
Lange, David
Av organisasjonen
I samme tidsskrift
Fire technology

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 12 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
v. 2.35.8