Using plate thermometer measurements to calculate incident heat radiation
RISE., SP – Sveriges Tekniska Forskningsinstitut.
RISE., SP – Sveriges Tekniska Forskningsinstitut.ORCID-id: 0000-0001-8670-062x
RISE., SP – Sveriges Tekniska Forskningsinstitut, SP Fire Research. Luleå Technical University, Sweden.
2013 (engelsk)Inngår i: Journal of fire sciences, ISSN 0734-9041, E-ISSN 1530-8049, Vol. 31, nr 2, s. 166-177Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The plate thermometer is a device used mainly to measure temperatures in fire resistance tests according to ISO 834-1 and EN 1363-1 and to measure the so-called adiabatic surface temperature. However, it can also be used to measure incident radiant heat flux (q·″inc) as a simpler, more robust and less-expensive alternative to water-cooled heat flux meters. The accuracy of the measured q·″inc is subject to simplifications in the heat transfer analysis model and uncertainties of parameters such as convective heat transfer coefficients, emissivities and ambient gas temperatures. This study investigates the accuracy of the model itself, isolated from the uncertainties of the physical surrounding, by comparing a simple one-dimensional model to the results of finite element modelling. The so-obtained model includes a heat transfer coefficient due to heat losses of the plate thermometer, found to be KPT = 8 W/m2 K and a heat storage lumped heat capacity CPT = 4200 J/m2 K for an ISO/EN standard plate thermometer. The model is also compared to real field experiments.

sted, utgiver, år, opplag, sider
2013. Vol. 31, nr 2, s. 166-177
Emneord [en]
Fire, heat flux meters, incident heat radiation, irradiance, measuring instrument, plate thermometer, thermal exposure
HSV kategori
Identifikatorer
URN: urn:nbn:se:ri:diva-6441DOI: 10.1177/0734904112459264Scopus ID: 2-s2.0-84875717918Lokal ID: 14423OAI: oai:DiVA.org:ri-6441DiVA, id: diva2:964279
Tilgjengelig fra: 2016-09-08 Laget: 2016-09-08 Sist oppdatert: 2023-05-22bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Sjöström, Johan

Søk i DiVA

Av forfatter/redaktør
Sjöström, Johan
Av organisasjonen
I samme tidsskrift
Journal of fire sciences

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 35 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
v. 2.43.0