Can particle counting replace conventional surveillance for airborne bacterial contamination assessments?: A systematic review using narrative synthesis
University of Gothenburg, Sweden.
University of Gothenburg, Sweden.
RISE Research Institutes of Sweden, Material och produktion, Metodik för produktframtagning.ORCID-id: 0000-0002-3034-6745
University of Gothenburg, Sweden.
Vise andre og tillknytning
2023 (engelsk)Inngår i: American Journal of Infection Control, ISSN 0196-6553, E-ISSN 1527-3296, Vol. 51, nr 12, s. 1417-Artikkel, forskningsoversikt (Fagfellevurdert) Published
Abstract [en]

Background: Bacterial airborne contamination in the operating room during surgery indicates an increased risk for surgical site infection. The conventional surveillance method for bacteria in the air is by air sampling, plating, and counting of colony-forming units (CFU). Particle counting measures particles in the air, typically in sizes of 1-20 µm, and has been suggested as an alternative to CFU measurements. The primary aim was to investigate the correlation between the number of airborne CFU and particles during surgery. The secondary aim was to explore whether different ventilation settings influence the correlation between CFU and particles. Methods: The databases Cochrane, Embase, and Medline were searched for relevant publications. Due to the heterogeneity of the data, meta-analysis was not possible and a narrative analysis was performed instead. Results: The review included 11 studies. Two of the studies (n = 2) reported strong correlation between particles and CFU (Rp = 0.76 and Rc = 0.74). The remaining studies observed moderate correlation (n = 3), low correlation (n = 3), or no correlation (n = 3). Based on the primary results from this study, ventilation attribution to distinguish the correlation between particles and CFU had no or little contribution. Conclusions: Due to the lack of convincing evidence of correlation and lack of high-quality studies performing measurements in a standardized way, the studies could not provide the necessary evidence that show that particle counting could be used as a substitution for conventional air bacterial assessment. Further studies are warranted to strengthen the conclusion. © 2023 The Authors

sted, utgiver, år, opplag, sider
Elsevier Inc. , 2023. Vol. 51, nr 12, s. 1417-
Emneord [en]
Air quality, Air sampling, Colony forming units, Microbial contamination, Operating room
HSV kategori
Identifikatorer
URN: urn:nbn:se:ri:diva-65601DOI: 10.1016/j.ajic.2023.05.004Scopus ID: 2-s2.0-85162128032OAI: oai:DiVA.org:ri-65601DiVA, id: diva2:1777547
Tilgjengelig fra: 2023-06-29 Laget: 2023-06-29 Sist oppdatert: 2024-06-07bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Björn, Camilla

Søk i DiVA

Av forfatter/redaktør
Björn, Camilla
Av organisasjonen
I samme tidsskrift
American Journal of Infection Control

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 19 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
v. 2.43.0