Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
High-Fire-Resistance Glulam Connections for Tall Timber Buildings
RISE Research Institutes of Sweden, Säkerhet och transport, Brand och Säkerhet.ORCID-id: 0000-0002-7663-1525
RISE Research Institutes of Sweden, Samhällsbyggnad, Bygg och fastighet.ORCID-id: 0000-0001-8970-7114
RISE Research Institutes of Sweden, Samhällsbyggnad, Bygg och fastighet.ORCID-id: RuneZ@ri.se
RISE Research Institutes of Sweden, Säkerhet och transport, Brand och Säkerhet.
Vise andre og tillknytning
2019 (engelsk)Rapport (Annet vitenskapelig)
Abstract [en]

Tall timber buildings generally require fire resistance ratings of 90 minutes, 120 minutes or more. The vast majority of fire tested structural timber connections, however, did not reach a fire resistance that was relevant for these buildings. Commonly timber connections between glued laminated timber members comprise of exposed steel fasteners, such as bolts, screws, nails and dowels. However, it has previously been concluded that connections with exposed steel fasteners, generally do not achieve fire resistance ratings of 30 minutes and are, therefore, inadequate to be implemented in tall timber buildings without fire encapsulation. The research project presented in this report consists of four connection fire tests that are designed to achieve structural fire resistance ratings of 90 minutes, using different design strategies. This goal was achieved for all tested column-beam connections. A single test of a moment resisting connection did not lead to a fire resistance rating of 90 minutes, due to timber failure at the smallest cross-section after 86 minutes. The low temperature of the steel fasteners and the limited rotation of the connection, however, suggest that the connection would have been capable of achieving a 90 minutes fire resistance rating if larger beam cross-sections would be used.

sted, utgiver, år, opplag, sider
2019.
Serie
RISE Rapport ; 2019:26
HSV kategori
Identifikatorer
URN: urn:nbn:se:ri:diva-59183ISBN: 978-91-88907-52-3 (digital)OAI: oai:DiVA.org:ri-59183DiVA, id: diva2:1657044
Tilgjengelig fra: 2022-05-09 Laget: 2022-05-09 Sist oppdatert: 2024-05-17bibliografisk kontrollert

Open Access i DiVA

fulltext(2128 kB)303 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 2128 kBChecksum SHA-512
a94dd6ed15223072fa31bede7905cbe988e8075fb2730598b215412fdce57c3b71514a8cdd97fa26d6985753afb479888ad3cc315ef90c71f09ce35ce761266d
Type fulltextMimetype application/pdf

Person

Brandon, DanielLandel, PierreZiethén, RuneJust, Alar

Søk i DiVA

Av forfatter/redaktør
Brandon, DanielLandel, PierreZiethén, RuneJust, Alar
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 310 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

isbn
urn-nbn

Altmetric

isbn
urn-nbn
Totalt: 470 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
v. 2.47.0