RoBound – Ro-ro space boundary fire protection – Smoke spread through in A class divisions
RISE Research Institutes of Sweden, Säkerhet och transport, Fordon och automatisering. (Fire Safe Transport)ORCID-id: 0000-0002-7874-2405
RISE Research Institutes of Sweden, Säkerhet och transport, Säkerhetsforskning. (Fire Safe Transport)ORCID-id: 0000-0002-2049-6213
RISE Research Institutes of Sweden, Säkerhet och transport, Brandteknik.
2020 (engelsk)Rapport (Annet vitenskapelig)
Abstract [en]

The International Maritime Organization, through its correspondence group on fire safety of ro-pax ships, has underlined the need for more scientific studies regarding the performance of boundaries in case of a ro-ro space fire, especially to prevent fire and smoke spread to accommodation spaces. Following these discussions, Swedish Flag State has underlined the issue of the smoke tightness of doors in A class divisions. While smoke tightness is a requirement for A class divisions, the fire resistance test method in the FTP Code is not designed to evaluate hazards associated with smoke spread.RISE has carried out the RoBound project to meet this need.To increase the understanding of this weakness in the FTP Code, RISE has performed experimental tests of two almost identical doors. The only difference between the two doors was the presence or not of an intumescent joint between the leaf and the frame of the door, intended to prevent the passage of smoke. The doors were exposed to the test for fire boundaries in Part 3 of the FTP Code, which exposes specimens to a simulated fire by a temperature increase according to the standard fire curve ISO 834.A modification of the standard experimental rig was added and consisted of the addition of a canopy above the tested doors to gather and measure the rate of carbon dioxide to quantify the amount of smoke leaking from the doors. This set up of canopy and measurement rig was taken from the standard EN 81-58 which is applied for elevator doors acting as fire barriers.The results of the tests showed that both doors marginally failed the A-60 integrity criteria since there was presence of a sustained flame at the unexposed side before 60 minutes of test. However, both doors satisfied to the insulation criteria by maintaining a rise of temperature lower than 140 °C in average at the unexposed side. The main difference between the doors was that the door with the intumescent joints presented a rate of smoke leakage which was almost half of that of the fire door without intumescent joints.This result clearly shows the importance of evaluating the smoke tightness of A class doors during testing and the need

sted, utgiver, år, opplag, sider
2020. , s. 19
Serie
RISE Rapport ; 2021:70
Emneord [en]
ro-ro space, ro-ro deck, SOLAS, guidance, open ro-ro space, closed ro-ro space, smoke spread, A class division, door
HSV kategori
Identifikatorer
URN: urn:nbn:se:ri:diva-54755ISBN: 978-91-89385-60-3 (digital)OAI: oai:DiVA.org:ri-54755DiVA, id: diva2:1576815
Forskningsfinansiär
Swedish Transport Administration, TRV 2019/96119The Swedish Mercantile Marine FoundationTilgjengelig fra: 2021-07-01 Laget: 2021-07-01 Sist oppdatert: 2023-11-02bibliografisk kontrollert

Open Access i DiVA

fulltext(2747 kB)148 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 2747 kBChecksum SHA-512
f00d27759c064ab1503f7fc2af5cced8f6378429f6800df25beb366ddfea8fdf39698ab8361680c295f45d94bf10127ec747aa9424f4820144c7cfaa8ab0db3a
Type fulltextMimetype application/pdf

Person

Mindykowski, PierrickOlofsson, Anna

Søk i DiVA

Av forfatter/redaktør
Mindykowski, PierrickOlofsson, Anna
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 155 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

isbn
urn-nbn

Altmetric

isbn
urn-nbn
Totalt: 374 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
v. 2.43.0