Calibration of hydrogen Coriolis flow meters using nitrogen and air and investigation of the influence of temperature on measurement accuracy
NEL, UK.
METAS, Switzerland.
CESAME-EXADEBIT SA, France.
RISE Research Institutes of Sweden, Säkerhet och transport, Mätteknik.ORCID-id: 0000-0001-5118-0150
2021 (engelsk)Inngår i: Flow Measurement and Instrumentation, ISSN 0955-5986, E-ISSN 1873-6998, Vol. 79, artikkel-id 101915Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The performance of four Coriolis flow meters designed for use in hydrogen refuelling stations was evaluated with air and nitrogen by three members of the MetroHyVe JRP consortium; NEL, METAS and CESAME EXADEBIT. A wide range of conditions were tested overall, with gas flow rates ranging from (0.05–2) kg/min and pressures ranging from (20–86) bar. The majority of tests were conducted at nominal pressures of either 20 bar or 40 bar, in order to match the density of hydrogen at 350 bar and 20 °C or 700 bar and −40 °C. For the conditions tested, pressure did not have a noticeable influence on meter performance. When the flow meters were operated at ambient temperatures and within the manufacturer's recommended flow rate ranges, errors were generally within ±1%. Errors within ±0.5% were achievable for the medium to high flow rates. The influence of temperature on meter performance was also studied, with testing under both stable and transient conditions and temperatures as low as −40 °C. When the tested flow meters were allowed sufficient time to reach thermal equilibrium with the incoming gas, temperature effects were limited. The magnitude and spread of errors increased, but errors within ±2% were achievable at moderate to high flow rates. Conversely, errors as high as 15% were observed in tests where logging began before temperatures stabilised and there was a large difference in temperature between the flow meter and the incoming gas. One of the flow meters tested with nitrogen was later installed in a hydrogen refuelling station and tested against the METAS Hydrogen Field Test Standard (HFTS). Under these conditions, errors ranged from 0.47% to 0.91%. Testing with nitrogen at the same flow rates yielded errors of −0.61% to −0.82%. © 2021 The Authors

sted, utgiver, år, opplag, sider
Elsevier Ltd , 2021. Vol. 79, artikkel-id 101915
Emneord [en]
Coriolis, Flow meter, Hydrogen, Refuelling station, Air refueling, Errors, Flow measurement, Flow of gases, Flow rate, Low temperature testing, Nitrogen, Temperature, Coriolis flowmeters, Field test, High-flow rate, Hydrogen refuelling stations, Measurement accuracy, Nominal pressures, Thermal equilibriums, Transient conditions, Flowmeters
HSV kategori
Identifikatorer
URN: urn:nbn:se:ri:diva-52600DOI: 10.1016/j.flowmeasinst.2021.101915Scopus ID: 2-s2.0-85102017405OAI: oai:DiVA.org:ri-52600DiVA, id: diva2:1538522
Merknad

Funding details: European Metrology Programme for Innovation and Research, EMPIR; Funding details: Horizon 2020; Funding text 1: The EMPIR project ?16ENG01 MetroHyVe? has received funding from the EMPIR programme co-financed by the Participating States and from the European Union's Horizon 2020 research and innovation programme.

Tilgjengelig fra: 2021-03-19 Laget: 2021-03-19 Sist oppdatert: 2021-03-24bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Büker, Oliver

Søk i DiVA

Av forfatter/redaktør
Büker, Oliver
Av organisasjonen
I samme tidsskrift
Flow Measurement and Instrumentation

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 77 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
v. 2.45.0