Planning and operation of an integrated energy system in a Swedish building
KTH Royal Institute of Technology, Sweden.
KTH Royal Institute of Technology, Sweden; Mälardalen University, Sweden.
RISE - Research Institutes of Sweden, Säkerhet och transport, Elektronik.ORCID-id: 0000-0002-1226-0788
Tianjin University, China.
Vise andre og tillknytning
2019 (engelsk)Inngår i: Energy Conversion and Management, ISSN 0196-8904, E-ISSN 1879-2227, Vol. 199, artikkel-id 111920Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

More flexibility measures are required due to the increasing capacities of variable renewable energies (VRE). In buildings, the integration of energy supplies forms integrated energy systems (IES). IESs can provide flexibility and increase the VRE penetration level. To upgrade a current building energy system into an IES, several energy conversion and storage components are needed. How to decide the component capacities and operate the IES were investigated separately in studies on system planning and system operation. However, a research gap exists that the system configuration from system planning is not validated by actual operation conditions in system operation. Meanwhile, studies on system operation assume that IES configurations are predetermined. This work combines system planning and system operation. The IES configuration is determined by mixed integer linear programming in system planning. Actual operation conditions and forecast errors are considered in system operation. The actual operation profiles are obtained through year-round simulations of different energy management systems. The results indicate that the system configuration from system planning can meet energy demands in system operation. Among different energy management systems, the combination of robust optimization and receding horizon optimization achieves the lowest yearly operation cost. Meanwhile, two scenarios that represent high and low forecast accuracies are studied. Under the high and low forecast accuracy scenarios, the yearly operation costs are about 4% and 6% higher than that obtained from system planning.

sted, utgiver, år, opplag, sider
Elsevier Ltd , 2019. Vol. 199, artikkel-id 111920
Emneord [en]
Building, Integrated energy system, MILP, Planning and operation, Robust optimization
HSV kategori
Identifikatorer
URN: urn:nbn:se:ri:diva-39915DOI: 10.1016/j.enconman.2019.111920Scopus ID: 2-s2.0-85071397120OAI: oai:DiVA.org:ri-39915DiVA, id: diva2:1356523
Merknad

 Funding details: China Scholarship Council, CSC; Funding text 1: This work has received funding from KKS Future Energy Profile through the project iREST and FREE. Yang Zhang acknowledges the financial support from China Scholarship Council (CSC).

Tilgjengelig fra: 2019-10-01 Laget: 2019-10-01 Sist oppdatert: 2019-10-01bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Lundblad, Anders Olof

Søk i DiVA

Av forfatter/redaktør
Lundblad, Anders Olof
Av organisasjonen
I samme tidsskrift
Energy Conversion and Management

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 67 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
v. 2.43.0