Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
CLT compartment fire test
RISE - Research Institutes of Sweden (2017-2019), Säkerhet och transport, Safety. Tallinn University of Technology, Estonia.ORCID-id: 0000-0002-8001-401x
RISE - Research Institutes of Sweden (2017-2019), Säkerhet och transport, Safety.ORCID-id: 0000-0002-7663-1525
Tallinn University of Technology, Estonia.
Estonian Academy of Security Sciences, Estonia.
Vise andre og tillknytning
2018 (engelsk)Inngår i: WCTE 2018 - World Conference on Timber Engineering, 2018Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

New high-rise timber buildings are planned to be built in the near future all around the world. The fire protection concepts are not always considering natural fire scenarios. As timber is a combustible material, it can contribute to the fire within and outside of the fire compartment. For buildings with cross-laminated timber (CLT) elements the possible fall-off of lamellas should be considered because of the risk for second flashover, which can lead to a continuous fire. However, in case fire service interference or sprinkler activation is absent or inefficient, it may be necessary to design a building so that it leads to a decaying fire. Additionally, it is important to limit fire spread to neighbouring compartments. This paper discusses a compartment test of a two-story building made of CLT performed in Estonia to study delamination behaviour and consequences in compartments with realistic ventilation conditions. State-of-the art solutions to limit fire spread from the first floor into the second floor were applied. This involved robust design of connections, penetrations through the compartment boundary and the façade. The paper provides a description and analysis of the test.

sted, utgiver, år, opplag, sider
2018.
Emneord [en]
Compartment test, Cross laminated timber, Fall-off of lamella, Physically based fire, Fire protection, Floors, Laminating, Timber, Wooden buildings, Combustible materials, Compartment fires, Cross laminated, Fire compartments, Physically based, Protection concepts, Sprinkler activation, Fires
HSV kategori
Identifikatorer
URN: urn:nbn:se:ri:diva-36680Scopus ID: 2-s2.0-85058162315OAI: oai:DiVA.org:ri-36680DiVA, id: diva2:1273579
Konferanse
2018 World Conference on Timber Engineering, WCTE 2018, 20 August 2018 through 23 August 2018
Tilgjengelig fra: 2018-12-21 Laget: 2018-12-21 Sist oppdatert: 2023-05-22bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Scopus

Person

Just, AlarBrandon, DanielSjöström, Johan

Søk i DiVA

Av forfatter/redaktør
Just, AlarBrandon, DanielSjöström, Johan
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric

urn-nbn
Totalt: 4872 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
v. 2.43.0