Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Fire Safety of CLT Buildings with Exposed Wooden Surfaces
RISE - Research Institutes of Sweden, Säkerhet och transport, Safety.ORCID-id: 0000-0002-7663-1525
RISE - Research Institutes of Sweden, Säkerhet och transport, Safety.ORCID-id: 0000-0002-8001-401x
2018 (engelsk)Konferansepaper, Publicerat paper (Annet vitenskapelig)
Abstract [en]

An increasing number of tall buildings made of CLT have been built in recent years. Current architectural trends involve having visible timber surfaces in these tall CLT structures. This results in new fire safety challenges, especially because fire service interference is increasingly difficult for increasingly tall buildings.

 

Recently, a number of research projects involving large scale compartment fire testing studied the development of fires in (1) compartments with a fully encapsulated CLT structure and (2) compartments with exposed CLT surfaces. The studies have shown that sufficient gypsum board protection can avoid the involvement of CLT in a fire. However, fall-off of the base layer of gypsum boards during can result in continuous fires that do not extinguish without fire surface interference, as during fall-off large areas of initially protected timber surfaces start to contribute as fuel to the fire.

 

If CLT is exposed to a fire, fire induced delamination of CLT (also lamella fall-off or char fall-off) could occur due to weakening of bond lines within the CLT. During fire induced delamination the exposed lamella falls from the CLT and a new relatively cold timber surface becomes exposed to potentially high temperatures, which effectively makes additional fuel suddenly available to a fire.

 

Very recent studies involved the development of CLT products that are not subject to delamination. The studies indicate that the use of (a) sufficient fire protection, (b) CLT products with thermally resistant adhesives and (c) a limit regarding the surface area of CLT that can be exposed, result in fires that decay and eventually self-extinguish.

This paper reviews the studies and includes a summary of conclusions.

sted, utgiver, år, opplag, sider
2018.
HSV kategori
Identifikatorer
URN: urn:nbn:se:ri:diva-36537OAI: oai:DiVA.org:ri-36537DiVA, id: diva2:1266158
Konferanse
4th Forum World Building Nordic Växjö
Tilgjengelig fra: 2018-11-27 Laget: 2018-11-27 Sist oppdatert: 2019-06-27bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Personposter BETA

Brandon, DanielJust, Alar

Søk i DiVA

Av forfatter/redaktør
Brandon, DanielJust, Alar
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric

urn-nbn
Totalt: 160 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
v. 2.35.7