Rain resistance of façades with façade details: A summary of three field and laboratory studies
RISE - Research Institutes of Sweden, Samhällsbyggnad, Byggteknik. Chalmers University of Technology, Sweden.ORCID-id: 0000-0003-4211-4885
2018 (engelsk)Inngår i: Journal of Building Physics, ISSN 1744-2591, E-ISSN 1744-2583, Vol. 41, nr 6, s. 521-532Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

ne of the main functions of the exterior walls and façades is to protect the indoor and the sensitive parts of construction from the outdoor climate. Exposure of driving rain is the most prominent moisture source a wall has to resist. Despite this, there is a lack of information on rain resistance. Field measurements on real-life external walls show that recurrent water leakage under driving rain conditions is observed in five out of seven new-built houses in Sweden, including those with ventilated façades. About a 100 commercial laboratory façade tests, mounted by façade suppliers, and targeted laboratory experiments showed that it is almost impossible to achieve fully tight façade solutions, and keep them sealed. Nearly, all test walls with façade details leaked, almost regardless of façade type and sealing efforts. The results from field and laboratory measurements of rain resistance in new buildings in Sweden show that façades are usually not water-tight and also that very small deficiencies can cause substantial amount of water leakage. © 2017, © The Author(s) 2017.

sted, utgiver, år, opplag, sider
SAGE Publications Ltd , 2018. Vol. 41, nr 6, s. 521-532
Emneord [en]
Driving rain, EN 12865, measurements, moisture, rain intrusion, risk assessment, wall, water leakage, window, Laboratories, Leakage (fluid), Measurement, Walls (structural partitions), Windows, Field measurement, Laboratory experiments, Laboratory measurements, Laboratory studies, Rain
HSV kategori
Identifikatorer
URN: urn:nbn:se:ri:diva-33899DOI: 10.1177/1744259117713265Scopus ID: 2-s2.0-85046830183OAI: oai:DiVA.org:ri-33899DiVA, id: diva2:1211002
Merknad

Funding details: Energimyndigheten

Tilgjengelig fra: 2018-05-30 Laget: 2018-05-30 Sist oppdatert: 2023-05-25bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Olsson, Lars

Søk i DiVA

Av forfatter/redaktør
Olsson, Lars
Av organisasjonen
I samme tidsskrift
Journal of Building Physics

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 57 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
v. 2.45.0